background image

User Manual

Page 7

Key Pad Features

Control Pads

Ope

rating

Instru

ctions

When you push the button to change operation modes, the unit will make a beep sound to indicate 
that it is changing modes.

CAUTION

Clean your unit occasionally to keep it looking new. Be sure to unplug the unit before 
cleaning to prevent chock or  re hazards.

NOTE

The control panel

.

(COMFORT) Button

Press to activate the comfort dehumidifying 
operation.

NOTE

When COMFORT function is turned on, 
set humidity is automatic and cannot be 
changed manually.

(FILTER) Button

This feature is a reminder to clean the Air Filter 
for more 

 operation. The LED (light) will 

illuminate after 250 hours of fan motor operation.

 

To reset after cleani

ter, press the Filter

 button and the light will go o .

(CONTINUE) Button

Press to activate the continuous dehumidifying 
operation.

Comfort 

dehumidifying

operation on

indicator light

Timer on/

 

indicator 

light

High fan

indicator 

light

Continuous operation

on indicator light

Auto defrost 

operation

on indicator 

light

 lter 

indicator light

LED

Display

Bucket full

indicator 

light

Summary of Contents for TDDP7011ES2

Page 1: ...al carefully and keep it for future reference change without prior notice for product improvement Consult with your dealer or the manufacturer for details version A 10 2017 us toshibalifestyle com TDDP7011ES2 Operating Instructions Installation Instructions Troubleshooting Tips Care and Cleaning ...

Page 2: ...hen installing operating and maintaining this product User Manual CAUTION Safety Precautions 3 6 Installation Instructions 13 Care and Cleaning 14 Troubleshooting Tips 15 Contact the authorized service technician for repair or maintenance of this unit The unit is not intended for use by young children or persons with reduced physical sensory or mental capabilities without supervision Young childre...

Page 3: ...and electric shock Ventilate room before operating the unit if there is a gas leak from other appliances Do not operate or stop the unit by inserting or pulling out the power cord plug It may cause electric shock Do not allow water to come into contact with any electric parts It may cause failure or electric shock Do not use the socket if it is loose or damaged re and electric shock Do not use or ...

Page 4: ...imb up on or sit on the unit You may be injured if you fall or if the unit falls over ngers lter once every two weeks ed service technician ower vases or other water container on top of the unit re the unit and unplug it from the main power supply immediately Visually inspect the unit to ensure there is no damage If you ed technician to avoid damage to the unit due to lightning Do not run cord und...

Page 5: ... or protected by a time delay fuse or ed electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not use extension cords or an adapter plugs with this unit However if it is er extension cord only available at most local hardware stores To avoid the possibility of personal injury always disconnect the the unit from power supply before installing ...

Page 6: ...t Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar F ront Power cord buckle 1 pc Insert the power cord buckle into the unit Fig 1 Fig 2 NOTE All the pictures in this manual are for illustrative purposes only The actual shape of the unit you purchased may be slightly di erent but its operations and function are similar OPERATING INSTRUCTION...

Page 7: ...COMFORT function is turned on set humidity is automatic and cannot be changed manually FILTER Button This feature is a reminder to clean the Air Filter for more operation The LED light will illuminate after 250 hours of fan motor operation To reset after cleani ter press the Filter button and the light will go o CONTINUE Button Press to activate the continuous dehumidifying operation Comfort dehum...

Page 8: ...or of the evaporator error Unplug the unit and plug it back in If error persists contact Customer Service P2 Bucket is full or bucket is not in right position Empty the bucket and replace it in the right position only available for the unit with no pump feature E3 Unit malfunction Unplug the unit and plug it back in If error persists contact Customer Service Eb Bucket is removed or not in right po...

Page 9: ...tart operation when the bucket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit Fig 5 Setting the Timer ON and Timer OFF rst press the Timer button the Timer OFF indicator light illuminates It indicates the Timer OFF program is initiated Press it again the Timer ON indicator light illuminates It indicates the Timer ON is initiated rst press t...

Page 10: ...t 2 Continuous draining oor drain by attaching the unit with a water hose Id Ø 5 16 not included with a female threaded end ID M 1 not included Remove the plastic cover from the back drain outlet of the unit and set aside then insert the drain hose through the oor drain or a suitable drainage facility See Fig 7 and Fig 8 When you remove the plastic cover if there is some water in the back drain ou...

Page 11: ...n 32 F 0 C otherwise water may become ice causing the water house to be blocked and the unit to stop operating Make sure to empty the bucket at least once a week a week when using the pump draining feature When the pump draining feature is not being used remove the pump drain hose from the outlet Removing Collected Water cont ...

Page 12: ...residential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bucket of water Allow at least 8 inches of air space on all sides of the unit for air circulation at least 16 inches for air outlet Place the unit in an area where the temperature will not fall belo...

Page 13: ...on use a vacuum cleaner or brush to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter lter outwards See Fig 10 lter with clean water then dry lter replace bucket 4 When not using the unit for long time pe...

Page 14: ... there are no curtains blinds or furniture blocking the front or back of the er The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 41 F 5 C There is a water vapor source in the room The unit makes a loud noise when operating lter Refer to Care and Cleaning section The unit is tilted instead of upright...

Page 15: ......

Reviews: