Toshiba TCB-PSMT1E Installation Manual Download Page 1

INSTALLATION MANUAL

Model:TCB-PSMT1E

Multi Tenant Kit

CB14800701(EN)

CB14800701(EN)

Precautions for safety

• Read these “Precautions for safety” carefully before installation work.
• The precautions described below include important items regarding safety. Observe them without fail. Understand the following details (indications and symbols) before reading the body text, and follow the 

Installation Manual.

The meanings of indications

WARNING

WARNING

Only a qualified installer or qualified service person is allowed to do installation work.

If installation is carried out by an unqualified individual, fire or electric shock may result.

Perform installation work reliably according to this Installation Manual.

Incomplete installation may cause electric shock, fire or abnormal operation.

Electrical work must be performed by a qualified installer or qualified service person in accordance with this Installation Manual. Appliance shall be installed in accordance with national wiring 

regulations. Inappropriate work may result in electric shock or fire.

Connect earth wire. (grounding work) Incomplete grounding cause an electric shock.

Before obtaining access to terminals, all supply circuits must be disconnected.

Install in a location where will not be touched by the general public.

To Disconnect the Appliance from Main Power Supply.

This appliance must be connected to the main power supply by means of a switch with a contact separation of at least 3 mm.

Connect the specified wires firmly and clamp them securely so that external force applied to the wires does not affect the connector pins.

Improper wire connection or clamping may result in fire or malfunction.

Do not disassemble, modify, repair or move the product yourself.

Doing so may cause fire, electric shock, injury or water leaks.

Ask a qualified installer or qualified service person to do any repairs or to move the product.

REQUIREMENT

• When the indoor unit with Multi Tenant Kit is turned on (breaker is ON) or turned off (breaker is OFF), the system will stop; however, it will restart after a short period.
• As there is a risk of electric shock during maintenance, turn off the power of the step-down transformer, as well as that of the indoor and outdoors units.

Accessories

Applications and Functions

When the tenant power supply (indoor unit power supply) is turned off, this kit converts the input voltage (24 V AC) to a DC voltage and supplies a low voltage 

to the indoor unit. 

Furthermore, it transmits a signal to notify that the indoor unit power supply has been turned off.

The LCD of the wired remote controller turns off and becomes inoperable.

Applicable indoor units

4-way Air Cassette Type, Concealed Duct Standard Type, Slim Duct Type, Under Ceiling Type, Console Type, 

High Wall Type, Concealed Duct High Static Pressure Type, Floor Standing Type, Floor Standing Cabinet Type,

Floor Standing Concealed Type

CAUTION

Install Slim Duct Type and Concealed Duct High Static Pressure Type (4 series) so that there is gravitational drainage.
(For details on gravitational drainage, refer to the installation manual of the indoor unit.)
Using a drain pump will cause a water leak.

Installation location 

Install the Multi Tenant Kit within the range that the supplied indoor unit connection cable will reach (within approximately 2 m).

The Multi Tenant Kit cannot be mounted to the indoor unit.
Install the Multi Tenant Kit in a location where service space can be provided.

Installation in the following locations is not possible.

• Location where combustible gas may leak.
• Location subject to direct sunlight.
• Location that becomes very hot and humid. (Use at an ambient temperature of 40°C or less.)
• Very dusty location
• Location near a kitchen, bathroom, or factory equipment.
For other prohibited locations, refer to the installation manual for the indoor unit.

WARNING

Text set off in this manner indicates that failure to adhere to 

the directions in the warning could result in serious bodily 

harm or loss of life if the product is handled improperly.

• After completion of installation, perform test run to check for any problems. 

Explain method of use and maintenance to the customer by following the descriptions in the manual. 
Ask customer to keep this manual at accessible place for future reference.

CAUTION

Text set off in this manner indicates that failure to adhere to 

the directions in the caution could result in serious bodily 

injury or damage to property if the product is handled 

improperly.

No.

Parts name 

Q'ty

Remarks

1

Multi Tenant Kit

1

2

Power cable

1

For power supply: 3 - cores with earth wire

3

Indoor unit connection cable (A)

1

Indoor communication cable: 6-pin

4

Indoor unit connection cable (B)

1

Indoor communication cable: 5-pin

5

Screws

4

For installing the Multi Tenant Kit

6

Wire joint

2

For power cable connection

7

Installation Manual

3

Must be handed over to the customer.

Installation procedure 

Use the four supplied screws to install the Multi Tenant Kit in a location with sufficient strength so that there is no risk of it falling.

External view

Wiring diagram

• The above wiring diagram shows the wiring for the Super Heat Recovery Multi (SHRM) specifications. For SMMS series, omit the flow selector unit part.
• For Super Heat Recovery Multi (SHRM), use a separate power supply that is shared with Multi Tenant Kit for the power supply of the flow selector unit.
• Install the flow selector unit and step-down transformer in a machine room or shared spaced away from tenants. 
• Install the circuit breaker in the AC24V power supply line.

• Locally procure a 24 V AC power supply power cable and step-down transformer that meet the following specifications.

Power cable specifications

3 - cores cabtire cable with earth wire, 1.25 - 2.0 mm

compliant with 60227 IEC 52

Step-down transformer specifications

Transformer (basic insulation specification) compliant with EN61558-1 / EN61558-2-6
Input voltage: 220-240 V AC, Output voltage: 24 V AC ±10%, 50 Hz, Load current: Max. 2.0 A

200

22

22

78

64.1

7.4

7.4

142.8

156

78

Unit: mm

Plate thickness: 0.7 mm

6 - Ø5.5 mounting hole

Approx.1800

Approx.1800

DC5V

24

9ᨺ

, 50 Hz

DC13V

TB1

COM

CN1

 

CN2

 

ᇫᇫ

CN4

CN3

220-240

9ᨺ

, 50 Hz

CN67

CN50

CN61

CN02

CN01

220-240

9ᨺ

, 50 Hz

R(L)

S(N)

CN81

220-240

9ᨺ

, 50 Hz

T6TOS-P930A

3

6

5

3

2

2

1

1

2 3

1

6

4 5

6

5

1

4

2 3

1

3

6

5

4

3

2

1

1
2
3

5

4

1

2

3

2 3

1

5

4

2

5

3 4

1

2
3

1

2

Indoor unit

BLACK

Step-down

Transformer

(Field supply)

Flow selector unit

Multi Tenant Kit

Circuit breaker

(Field supply) 

P.C.Board

WHITE

(RED)

(WHITE)

(YELLOW)

(WHITE)

(OPTION)

(YELLOW)

(WHITE)

(BLACK)

P.C.Board

RED

WHITE

(BLACK)

(GREEN)

(RED)

P.C.Board

Circuit breaker

(Field supply) 

Circuit breaker

(Field supply) 

Power supply

Power supply

Power supply

+DB14800701_01EN.fm  Page 1  Thursday, November 5, 2015  2:12 PM

Summary of Contents for TCB-PSMT1E

Page 1: ...e will reach within approximately 2 m The Multi Tenant Kit cannot be mounted to the indoor unit Install the Multi Tenant Kit in a location where service space can be provided Installation in the following locations is not possible Location where combustible gas may leak Location subject to direct sunlight Location that becomes very hot and humid Use at an ambient temperature of 40 C or less Very d...

Page 2: ...n plus remote controller RBC AMS51E Perform the advanced settings for the air conditioner Carry out the setting operation while the indoor unit is stopped Turn off the air conditioning unit before starting the setting operation 1 Push the MENU button to display the menu screen 2 Push and hold the MENU button and the button at the same time to display the Field setting menu Push and hold the button...

Page 3: ...e pour qu il soit accessible avec le câble de connexion environ 2 m Le kit multi locataire ne peut pas être monté sur l unité intérieure Installez le kit multi locataire dans un endroit avec suffisamment d espace L installation dans les endroits suivants n est pas possible Endroit où il existe un risque de fuite de gaz combustible Endroit soumis à la lumière directe du soleil Endroit qui devient t...

Page 4: ...E Effectuez les réglages avancés pour le climatiseur Réalisez les opérations de réglage pendant que l unité intérieure est à l arrêt Mettez le climatiseur hors tension avant de démarrer les opération de réglage 1 Appuyez sur la touche MENU pour afficher l écran de menu 2 Maintenez pressée la touche MENU et la touche en même temps pour afficher le Menu réglages Service Maintenez pressées les touche...

Page 5: ...del cavo dell unità interna Il kit non può essere montato sull unità interna Deve essere installato in modo da garantire lo spazio necessario per le manutenzioni Non lo si deve installare In un ambiente ove si possano verificare perdite di gas infiammabili In un luogo esposto direttamente al sole In un ambiente molto caldo e umido la temperatura non deve superare 40 C In un ambiente molto polveros...

Page 6: ...legamento unità interna B CN1 CN3 CN2 TB1 La visualizzazione varia secondo il modello di unità interna Telecomando Lite Vision plus RBC AMS51E Con questa funzione si eseguono le impostazioni avanzate del condizionatore Prima di eseguirle è necessario spegnere l unità interna cioè il condizionatore Prima di effettuare l impostazione spegnere il condizionatore 1 Premere MENU per visualizzare la pagi...

Reviews: