Universal Slot PCB Wiring
Cable Lengths
10-18
Strata DK I&M 6/00
1. Indicate if HDCB or electronic telephone.
2. HDSS console number 1~8 is not allowed.
3. Indicate if BGM or electronic telephone is connected; BGM connects to VT and VR, circuit 8 only (DT and DR not used).
Notes
●
Indicate if standard telephone, voice mail port, electronic telephone, HDCB (allowed HDCB
port numbers: 004, 012, 020, 028) or separate BGM source.
●
OCA wiring not shown, see MDF-to-electronic telephone wiring.
Figure 10-16 PESU Station MDF Cross Connect Record
MDF Block Number
KSU Slot Number
Color Code
Designation
CKT
Number
Port
Number
Intercom
Number
Device/Standard Telephone/Electronic
Telephone Location
W-Bl
T
1
Bl-W
R
W-O
Not Used
O-W
Not Used
W-G
T
2
G-W
R
W-Br
Not Used
Br-W
Not Used
W-S
Not Used
3
NA
NA
S-W
Not Used
R-Bl
Not Used
Bl-R
Not Used
R-O
Not Used
4
NA
NA
O-R
Not Used
R-G
Not Used
G-R
Not Used
R-Br
VT
5
See Note 1.
Br-R
VR
R-S
DT
S-R
DR
Bk-Bl
VT
6
Bl-Bk
VR
Bk-O
DT
O-Bk
DR
Bk-G
VT
7
See Note 2.
G-Bk
VR
Bk-Br
DT
Br-Bk
DR
Bk-S
VT
8
See Notes 2 and 3.
S-Bk
VR
Y-Bl
DT
Bl-Y
DR
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...