DK424i Installation
Step 5: Install Reserve Power
7-38
Strata DK I&M 6/00
Notes
●
When floor mounting the DK424i, the batteries must be installed by a licensed electrician per
local electric code using conduit. (See
●
Batteries should be installed in a customer-supplied commercial battery box or enclosed rack.
To BBDB
Battery Distribution Box
F1~F4 Battery
Fuses 250VAC/15A
BCCB
BATT
-
+
AC
N
L
Battery Wire Specifications
#10 AWG minimum (2 pairs)
42A max.
AC Wire
Specifications:
BCCB120
#10 AWG
29A max.
BBCB240
#12 AWG
18A max.
BCCB120 (top view)
3 outlets
NEMA:5-15R
Fused: 250VAC/15A
Rated: 125VAC/15A
BCCB240 (top view)
2 outlets
NEMA:6-20R
Not Fused
Rated: 250VAC/20A
5047
F3
F1
F4
F2
F3
F1
F4
F2
Conduit
Holes to 1/2 inch trade size
WARNING!
BCCB conduit boxes must be
installed by a certified electrician.
From
reserve
battery
From
20A dedicated
circuit
Figure 7-23 BCCB AC Power and Battery Connections
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...