Toll Restriction
Program 47 Toll Restriction Exception Codes (Tables 01~08)
4-22
Strata DK40 Programming Manual Spring 1999
Program 47
Toll Restriction Exception Codes (Tables 01~08)
Program Type:
Toll Restriction
Initialised Default:
Assigns no exception/override codes to tables
Program 47 Overview
This program allows up to eight STD, International or Local codes to be assigned to a Toll
Restriction Class that are the opposite of what is defined in
. Each exception
table can only be programmed with one number that is from one to seven digits long.
For instance, if Program 46 denies STD code 01932 in Class 1, entering STD code 0193282
into an Exception table that is assigned to that class in Program 47 will allow any telephone
number that starts with 01932-82XXXX. It will not however allow any number that starts
with 01932-1, 01932-2, 01932-3 etc and also any telephone numbers that start with 01932-
81, 01932-83, 01932-84 etc.
As the Exception table could contain a Local code all digits that are to be dialled must be
entered including the leading '0' as not all local numbers start with a '0'.
(QWHU 3URJ 0RGH
0
6SNU
7 :
+ROG 6SNU
+ROG
0
6SNU
& &
+ROG
0
6SNU
& &
+ROG
Processor
Exception Table
DK40
01~08
Exception
Table
DATA = Record of Exception/Override Code
08
07
06
05
04
03
02
01
DATA =
Enter or display Exception/Override code.
SELECT = Exception Table (01~08)
A new exception table is needed for each code that is an exception to restriction.