2. Wrap the cables in with the mesh tie. The purpose of the wrap is to shield the cables from EMI/RFI
effects. See
Front
Cable Shield
(B50MT)
1. Attach lead to grounding screw.
2. Wrap mesh around
communication cables.
3. Secure with velcro strap.
CAUTION!
Mesh strap should not touch
cabinet metal surfaces.
Part No. B50MT comes with the Base
Cabinet. It must be ordered separately
for each Remote Cabinet pair.
25-Pair
Amphenol
Cables
5045
To MDF
Knock Out Plastic
To
MDF
Top
25-Pair
Amphenol
Cables
Figure 3-10
Cabinet Amphenol Cables