5. DIAGNOSTIC TEST OPERATION << Preliminary version >>
EO18-12017
5.4 Serviceman Diagnostic Test Program
5- 25
5.4.4.5 USB IDCR Test
In this test, it is checked if the IDCR installed into the PKBST-52 reads the data stored in the magnetic card
correctly.
(1) Operation
procedure
1. Select the
USB IDCR Test(5)
button on the Keyboard Test Menu screen.
2. For creating master data, slowly swipe the card through the IDCR.
3. When the master data is recognized, the data is displayed in the Master edit box.
4. When a magnetic card is swiped through the IDCR, the read data is displayed in the Data edit box. If it
corresponds with the master data, an OK count increases. If not, an NG count increases.
5. Click the
END
button to terminate the test. At this time, OK is displayed when none of NG was counted,
whereas NG is displayed when one or more NG was counted.
(2) Error
code
Result
Error Code
Error Code Ex
Remarks
1
0
0
None of NG was counted in this test, then the
test was terminated.
-1
0
0
One or more NG was counted in this test, then
the test was terminated.
-1
1
Device open error
-1 2
See IDCR Device Control
Function Error Code Table.
Key tone setting error
-1
3
0
Data comparison error
-1
4
0
The driver could not acquire the read data
correctly.