Test Program for Field.
Satellite U840 Tests and Diagnostics Manual
11
3.4 System Test
To execute the System Test select 01 from the Diagnostic Test Menu, press Enter and follow
the directions on the screen. The System Test contains three subtests. Move the highlight bar
to the subtest you want to execute and press Enter.
Subtest 01
FAN ON/OFF Checking
Select 1,2,3 to control FAN on/off , 1=Fan on , 2=Fan off , 3=Exit .
[BOIFAN.EXE] Program Version : 1.0
1: Fan On 2: Fan Off 3: Exit
Fan1 Status On Fan1RPM : 5000 or Fan1 Status OFF Fan1RPM : 0
Fan2 Status On Fan2RPM : 2500 or Fan2 Status OFF Fan2RPM : 0
Subtest 02
Battery Test
This will display battery information for check , press [ESC] to exit .
[BOIPCU.EXE] Program Version : 1.1 03-20-2010
voltage : 8314 mV Remaining capacity alarm : 730 mAh
temperature : 24.4 ‘C Remaining time alarm : 10 min
current : 0 mA Battery mode : 6001
average current : 0 mA AtRate : 0 mA
relative state of charge : 100 % At rate time to full : 65535 min
absolute state of charge : 95 % At rate time to empty : 65535 min
remaining capacity : 6873 mAh At rate O. K. : 1
full charge capacity : 6873 mAh Maximun error : 1 %
run time to empty : -1 min. Charging current : 0 mA
average time to empty : -1 min. Charging voltage : 8340 mA
average time to full : -1 min. Manufacturer name : Simplo
cycle count : 3 times Device name : NS3P2SZGI6WR
design capacity : 7310 mAh Device chemistry : LION
design voltage : 7400 mV Manufacturer data : 0
specification information : 3.1 Manufacture date : 11/16/2011
serial no. : 107
STATUS : INIT DISK FULL_CHG
Press [ESC] KEY to exit
Summary of Contents for Satellite U840 Series
Page 1: ...Satellite U840 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Page 18: ...Chapter 1 Hardware Overview Satellite U840 Maintenance Manual 960 Q08 15 ...
Page 24: ...2 1 Satellite U840 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Page 190: ...Satellite U840 Maintenance Manual 960 Q08 Appendix B Appendix B Board Layout B 1 System Board ...