Chapter 1 Hardware Overview
Satellite C800 and Satellite L800
Maintenance Manual (960-Q08)
25
1.7 Power Rails
Table 1-11 lists the power rail output specifications of chief river platform.
Table 1-11 Power supply output rating
Name
Power supply
(
Yes/No
)
Voltage [V]
Power OFF
Suspend mode
Power OFF
Boot mode
No Battery
+5VPCU
5
Yes
Yes
No
+5V
5
No
No
No
+3VPCU
3.3
Yes
Yes
No
+3V_S5
3.3
Yes
No
No
+3VSUS
3.3
Yes
No
No
+3V
3.3
No
No
No
+1.8VSUS
1.8
Yes
No
No
+SMDDR_VTERM
1.8
Yes
No
No
+SMDDR_VREF
1.8
Yes
No
No
+1.8V
1.8
No
No
No
+1.5V
1.5
No
No
No
+1.2V
1.25
No
No
No
+1.05v
1.05
No
No
No
+NB_CORE
1.0~1.2
No
No
No
VCC_CORE
0.7~1.2
No
No
No