Chapter 1 Hardware Overview
Satellite L730/Satellite 735/Satellite Pro 730 Maintenance Manual (960-Q08)
16
1.8.2 Battery Charging Control
Battery charging is controlled by a power supply microprocessor. The power supply
microprocessor controls power supply and detects a full charge when the AC adaptor and
battery are connected to the computer.
Battery Charge
When the AC adapter is connected, normal charging is used while the system is
turned on and quick charge is used while the system is turned off. Refer to the
following Table 1-8-2.
Power ON
Power OFF
6 cell
5 ~ 10 hours
about 5 hours
Table 1-8-2 Time required for charges of main battery
Charge is stopped in the following cases.
1. The main battery is fully charged
2. The main battery is removed
3. Main battery or AC adapter voltage is abnormal
4. Charging current is abnormal
Data preservation time
When turning off the power in being charged fully, the preservation time is as
following Table 1-8-3.
Sleep
Shut
down
6 cell
About 3 days
About 30 days