background image

 

TOSHIBA

 International Corp 

 
 
 
 

 

REMOTE STATUS ALARM PANEL 

 

RSAP 

INSTALLATION/INSTRUCTION MANUAL 

Summary of Contents for RSAP

Page 1: ...TOSHIBA International Corp REMOTE STATUS ALARM PANEL RSAP INSTALLATION INSTRUCTION MANUAL ...

Page 2: ... Figure 1 0 5 Remote Monitor Closed Hardwire Figure 1 1 6 Terminal Block Description Figure 2 0 7 Terminal Block Description Figure 2 1 8 Remote Monitor Open Figure 3 0 9 Remote Monitor Open Hardwired Figure 3 1 10 Remote Monitor Conduit Access Figure 4 0 11 Figure G8000 12 Figure 4200FA 15 50Kva 13 Figure 4200FA 80kVA 14 ...

Page 3: ... pairs of twisted wire from the RSAP to the customer accessible alarm contact terminal bar in the UPS module Refer to UPS manual for location 6 Referring to Figure 3 0 install 6 AA batteries Batteries will provide about eight 8 hours of run time in the event of an AC power failure Replace these batteries yearly for optimum performance 7 Referring to Figure 1 0 connect the power supply adapter into...

Page 4: ...audible alarm will beep intermittently 3 Inverter On LED The green LED is illuminated as long as the UPS inverter is operating 4 Output LED This green LED is illuminated as long as there is power to the critical load Either by the Inverter or Bypass 5 Load On Bypass LED This yellow LED is illuminated as long as the critical load is powered by the Bypass 6 AC Input LED This green LED is illuminated...

Page 5: ...5 ...

Page 6: ...REEN LED 11 ALARM SILENCE RED LED 2 BATTERIES ON YELLOW LED 3 INVERTER ON GREEN LED 4 OUTPUT TO CRITICAL LOAD GREEN LED 5 LOAD ON BYPASS YELLOW LED 12 INTERNAL MONITOR BATTERY OK YELLOW LED 10 BATTERY LOW VOLTAGE RED LED 9 INPUT FAILURE RED LED 8 OVERLOAD RED LED 7 UPS FAULT RED LED 6 AC INPUT ON GREEN LED AUDIBLE ALARM MONITOR RESET PUSHBUTTON MONITOR TEST PUSHBUTTON ALARM SILENCE PUSHBUTTON INTE...

Page 7: ...7 ...

Page 8: ... COMMON 9 ON BATTERIES 10 ON BATTERY COMMON 11 RECTIFIER 12 RECTIFIER COMMON 13 UPS FAILURE 14 UPS COMMON 15 LOW BATTERY 16 LOW BATTERY COMMON 17 OVERLOAD 18 OVERLOAD COMMON TERMINAL BLOCK DESCRIPTION LOCATED INSIDE BOX FIGURE 2 1 INTERNAL POWER SUPPLY HARDWIRE OPTION TB 1 3 BYPASS 4 BYPASS ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...llustration purposes only and is subject to change without notice TIC is not responsible for any errors or omissions DATE 04 06 06 Drawn by JE RSAP REMOTE ALARM STATUS PANEL 4200FA 80kVA RSAP TIC 4200FA 80 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 OUTPUT OVERLOAD COMMON LOW BATTERY COMMON UPS FAILURE COMMON RECTIFIER ON COMMON ON BATTERIES COMMON LOAD ON INVERTER COMMON LOAD ON BYPASS 16 COMMON 2 12 1 3...

Reviews: