background image

1

ACCESSORIES

PRECAUTIONS FOR SAFETY

WARNING 

WARNINGS ABOUT INSTALLATION

• Make sure to ask the qualified installation professional in electric work to install

the air conditioner.
If the air conditioner is inappropriate installed by yourself, it may cause water leak,
electric shock, fire, and so on.

• Ground the air conditioner without fail.

Do not connect the ground wire to gas pipe, water pipe, lightning rod or ground
wire of telephone. If the air conditioner is imperfectly grounded, it may cause
electric shock.

CAUTION

TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY

This appliance must be connected to the mains by means of a switch with a
contact separation of at least 3 mm.

The installation fuse (25A D type 

 ) must be used for the power

supply line of this conditioner.

WARNINGS ABOUT OPERATION

• Cleaning of the air filter and other parts of the air filter involves dangerous work in

high places, so be sure to have a service person do it. Do not attempt it yourself.
The cleaning diagram for the air filter is there for the service person, and not for
the customer.

• Avoid cooling the room too strong or exposing the human body to cool breeze for

a long time as it is bad for the health.

• When you notice something abnormal with the air conditioner (smells like some-

thing scorching, poor cooling, etc.), immediately turn off the main switch, the
circuit breaker, from the mains to stop the air conditioner, and contact the dealer.
If the air conditioner is continuously operated with something abnormal, it may
cause machine failure, electric shock, fire, and so on.

WARNINGS ABOUT MOVEMENT AND REPAIR

• Do not move or repair any unit by yourself.

Since there is high voltage inside the unit, you may get electric shock when
removing the cover and main unit.

• Whenever the air conditioner needs repair, make sure to ask the dealer to do it.

If it is repaired imperfectly, it may cause electric shock or fire.

• When moving the air conditioner for re-installing at another place, ask the dealer

to do it. If it is imperfectly installed, it may cause electric shock or fire.

Remote controller

(sold separately)

Installation plate

Screws for installation plate

Ø4mm x 25mm

FAN SPEED

TEMP.

F A N
COOL
D R Y
H E AT
AUTO

STANDBY
FILTER
PRE-HEAT
DEFROST
LOUVER
MANUAL

CENTRAL

CHECK

AUTO
F I X

LOUVER

Summary of Contents for RAV-SM560AT-E

Page 1: ... Installateur oder vom Lieferanten aushändigen Eine Bitte an den Installateur oder Lieferanten Bitte erklären Sie dem Käufer den Inhalt der Betriebsanleitung und händigen sie ihm aus Grazie di aver acquistato un condizionatore d aria TOSHIBA Prima di usare il condizionatore d aria leggere con attenzione questo manuale del proprietario Si raccomanda di tenere a portata di mano il Manuale del propri...

Page 2: ...gerante convenzionale R22 per prevenire la distruzione dello strato di ozono dell atmosfera terrestre ADOPCIÓN DE NUEVO REFRIGERANTE Este aparato de aire acondicionado es un modelo reciente que incorpora el nuevo refrigerante HFC R410A en lugar del refrigerante convencional R22 para así evitar daños en la capa de ozono ADOPÇÃO DO NOVO REFRIGERANTE Este ar condicionado é um modelo novo que adopta u...

Page 3: ...CESORIOS 49 PRECAUCIONES PARA SU SEGURIDAD 49 NOMBRE DE LOS COMPONENTES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 52 UTILIZACIÓN CORRECTA 54 FUNCIONAMIENTO CON AIRE SECO 55 ACESSÓRIOS 61 PRECAUÇÕES DE SEGURANÇA 61 NOME DAS PEÇAS 63 NOME E FUNÇÕES DOS INDICADORES E CONTROLOS 63 NOME E OPERAÇÕES DOS INDICADORES E CONTROLOS 64 ...

Page 4: ...ce person and not for the customer Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health When you notice something abnormal with the air conditioner smells like some thing scorching poor cooling etc immediately turn off the main switch the circuit breaker from the mains to stop the air conditioner and contact the dealer If the air c...

Page 5: ...the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is used in a closed room be careful of sufficient ventilation of the room Poor ventilation causes oxygen shortage Do not touch any switches with wet finger otherwise you may...

Page 6: ...n operation the OPERATION lamp is orange TEMPORARY button If you misplace or lose the remote controller or its batteries are exhausted push the TEMPORARY button 1 Open the air inlet grille to push theTEMPORARY button 2 Push the TEMPORARY button to start the air conditioner Push this button once again to stop it 3 Continue to push the button for 10 seconds to start cooling operation Preparing the f...

Page 7: ...set up temp display section 4 Operation mode display The selected operation mode is displayed 5 Fan mode display The selected fan mode is displayed LOW MED HIGH 6 Air volume fix display This is not displayed on this model 7 CENTRAL control display Displayed when used with the central remote controller etc 8 STANDBY display It is displayed when the operation cannot be performed though it is not an ...

Page 8: ...ual attached to each remote controller 1 Operation select button Selects desired operation mode 2 Air volume select button Selects the desired air volume mode 3 Set up temp button Adjusts the required room temperature Match to the desired set temperature by pushing 4 Filter reset button Resets Erases FILTER display 5 CHECK button When an error fault occurs on the air conditioner this button is use...

Page 9: ...ation mode with MODE button For every push of the button the display changes as right figure 2 Select air volume with the FAN button The display changes as follows LOW MED HIGH AUTO When air volume is AUTO air volume changes according to the room temperature 3 Determine the set up temperature by pushing the TEMP button 4 Push ON OFF button The operation lamp goes on and the operation starts STOP P...

Page 10: ...lly select either cooling heating or fan only operation depending on the outdoor temperature Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select Auto 3 Temperature button Set the desired temperature In case of cooling it starts the operation after approx 1 minute In case of heating the operation mode is selected in accordance with the room tempe...

Page 11: ... louver manually Always use the LOUVER button If you move the louver manually it may malfuction during operation If the louver malfunctions stop the air conditioner once and restart Adjust the horizontal air flow Preparation Take hold of the lever on the horizontal air flow louver and move them to adjust the air flow direction as you desire You can adjust the air flow at the left center and right ...

Page 12: ... The lamp will start to indicate after every 1000 hours of operation The FILTER lamp will be out when the TEMPORARY button is pushed The FILTER lamp will also be out when the FILTER button on the remote controller is pushed MAINTENANCE WARNING Before you clean the air conditioner be sure to turn off the circuit breaker or main power switch Cleaning of indoor unit and remote controller CAUTION Use ...

Page 13: ...left and right handles of the air filter and lift it up slightly then pull it downward to take it out from the filter holder 3 Remove the filters 4 Use a vacuum cleaner to remove the dust from the filters or wash them with water If you wash the air filters dry them in the shade Filter holder Filter holder Air filter 5 Insert the upper portion of the air filter aligning right and left edges on the ...

Page 14: ...ille is completely closed AIR CONDITIONER OPERATIONS AND PERFORMANCE 3 minute protection function A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is turned on This will protect the machine Heating operation characteristics Preheating operation The air conditioner will...

Page 15: ...Room temperature Less than 30 C PROBLEMS AND CAUSES CAUTION If any of the following conditions occur turn off the main power supply switch and immediately contact the dealer The indicator lamps flash at short intervals 5 Hz even though you have tried turning off the power supply and turning on again after 2 to 3 minutes Switch operation is erratic The main power fuse often blows out or the circuit...

Page 16: ...1075000645 ...