background image

AIR CONDITIONER

 

(SPLIT TYPE)

CLIMATISEUR

 

(TYPE SPLIT)

KLIMAGERÄT 

(SPLIT-SYSTEM)

CONDIZIONATORE D'ARIA

 (TIPO MULTIAMBIENTI)

APARATO DE AIRE ACONDICIONADO

 (TIPO SPLIT)

AR CONDICIONADO

 

(TIPO SPLIT)

AIRCONDITIONER

 (GESPLITST TYPE)

ÊËÉÌÁÔÉÓÔÉÊÏ

 (ÔÕÐÏÓ SPLIT)

<High-Wall Type>/<Type  mural  haut>
<Wandmontierter Typ>/<Tipo a condotto nascosto>
<Modelo de pared>/<Tipo Mural>

<Hoog-Wandtype>/<Ôýðïò Õøçëïý Ôïß÷ïõ>

Heat Pump Model/Modèle à thermopompe
Geräte mit Heizung/Modello con pompa di riscaldamento
Modelo con bomba de calor/Modelo de bomba térmica

Model met warmtepomp/ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò

Indoor Unit/Unité intérieure

Outdoor Unit/Unité extérieure

Raumeinheit/Unità interna

Außengerät/Unità esterna

Unidad interior/Unidade interior

Unidad exterior/Unidade exterior

Binnenunit/ÅóùôåñéêÞ ÌïíÜäá

Buitenunit/ÅîùôåñéêÞ ÌïíÜäá

RAV-SM560KRT-E

RAV-SM560AT-E

RAV-SM800KRT-E

RAV-SM800AT-E

OWNER’S MANUAL

MANUEL DU PROPRIETAIRE

BETRIEBSANLEITUNG

MANUALE DEL PROPRIETARIO

MANUAL DEL PROPIETARIO

MANUAL DO UTILIZADOR

GEBRUIKSAANWIJZING

ÏÄÇÃÉÅÓ ×ÑÇÓÇÓ

Thank you very much for purchasing TOSHIBA Air Conditioner.
Please read this owner's manual carefully before using your Air Conditioner.
• Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer).
Request to constructor or dealer
Please clearly explain the contents of the Owner’s manual and hand over it.

Nous vous remercions pour avoir choisi un climatiseur TOSHIBA.
Veuillez lire attentivement ce Manuel du propriétaire avant d’utiliser votre climatiseur.
• Assurez-vous que le constructeur (ou le revendeur) vous remette le “Manuel du propriétaire”

et le “Manuel d’installation”.

Demande au constructeur ou au revendeur
Veuillez expliquer clairement le contenu du Manuel du propriétaire et le remettre au client.

Wir danken Ihnen, dass Sie sich für ein TOSHIBA Klimagerät entschieden haben.
Bitte lesen Sie diese Betriebsanleitung, bevor Sie Ihr Klimagerät benutzen, sorgfältig.
• Lassen Sie sich die “Betriebsanleitung” und das “Installations-Handbuch” unbedingt vom Installateur oder vom Lieferanten aushändigen.
Eine Bitte an den Installateur oder Lieferanten:
Bitte erklären Sie dem Käufer den Inhalt der Betriebsanleitung und händigen sie ihm aus.

Grazie di aver acquistato un condizionatore d'aria TOSHIBA.
Prima di usare il condizionatore d'aria, leggere con attenzione questo manuale del proprietario.
• Si raccomanda di tenere a portata di mano il “Manuale del proprietario” e il “Manuale di installazione” ricevuti dal produttore (o dal rivenditore).
Richiesta al produttore o al rivenditore
Spiegare chiaramente il contenuto del Manuale del proprietario e consegnarne una copia all'utente.

Muchas gracias por haber adquirido el aparato de aire acondicionado TOSHIBA.
Lea atentamente este manual del propietario antes de utilizar el aparato de aire acondicionado.
• Asegúrese de que el fabricante (o distribuidor) le proporcione el “Manual del propietario” y el “Manual de instalación”.
Solicitud al fabricante o distribuidor
Explique con claridad el contenido del Manual del propietario y entréguelo al cliente.

Muito obrigada por adquirir o Ar Condicionado TOSHIBA.
Leia atentamente este manual do utilizador antes de utilizar o seu ar condicionado.
• Não se esqueça de receber o “Manual do utilizador” e o “Manual de inslatação” do fabricante (ou agente).
Pedido ao fabricante ou agente
Explique por favor o conteúdo do Manual do utilizador e entregue-o.

Hartelijk dank voor uw keuze voor een airconditioner van TOSHIBA.
Lees deze gebruiksaanwijzing zorgvuldig door voordat u de airconditioner gaat gebruiken.
• Zorg ervoor dat u zowel de ‘gebruiksaanwijzing’ als de ‘installatiehandleiding’ van de installateur (of leverancier) krijgt.
Verzoek aan de installateur of de leverancier
Leg de inhoud van de gebruiksaanwijzing duidelijk uit en overhandig de gebruiksaanwijzing nadien aan de klant.

Óáò åõ÷áñéóôïýìå ðïëý ðïõ ðñïôéìÞóáôå ãéá ôçí áãïñÜ óáò Ýíá Êëéìáôéóôéêü TOSHIBA.
Ðáñáêáëïýìå äéáâÜóôå ðñïóå÷ôéêÜ ôéò ïäçãßåò ÷ñÞóçò ðñéí áðü ôç ÷ñÞóç ôïõ Êëéìáôéóôéêïý.
• Âåâáéùèåßôå üôé ï êáôáóêåõáóôÞò (Þ ï ðùëçôÞò) óáò ðáñÝäùóå êáé ôéò “Ïäçãßåò ×ñÞóçò” êáé ôï “Åã÷åéñßäéï ÅãêáôÜóôáóçò”.
ÐáñÜêëçóç ãéá ôïí êáôáóêåõáóôÞ Þ ôïí ðùëçôÞ
Ðáñáêáëþ åîçãÞóôå ìå óáöÞíåéá ôá ðåñéå÷üìåíá ôùí Ïäçãéþí ×ñÞóçò êáé ðáñáäþóôå ôï.

Summary of Contents for RAV-SM560AT-E

Page 1: ... Installateur oder vom Lieferanten aushändigen Eine Bitte an den Installateur oder Lieferanten Bitte erklären Sie dem Käufer den Inhalt der Betriebsanleitung und händigen sie ihm aus Grazie di aver acquistato un condizionatore d aria TOSHIBA Prima di usare il condizionatore d aria leggere con attenzione questo manuale del proprietario Si raccomanda di tenere a portata di mano il Manuale del propri...

Page 2: ...gerante convenzionale R22 per prevenire la distruzione dello strato di ozono dell atmosfera terrestre ADOPCIÓN DE NUEVO REFRIGERANTE Este aparato de aire acondicionado es un modelo reciente que incorpora el nuevo refrigerante HFC R410A en lugar del refrigerante convencional R22 para así evitar daños en la capa de ozono ADOPÇÃO DO NOVO REFRIGERANTE Este ar condicionado é um modelo novo que adopta u...

Page 3: ...CESORIOS 49 PRECAUCIONES PARA SU SEGURIDAD 49 NOMBRE DE LOS COMPONENTES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 52 UTILIZACIÓN CORRECTA 54 FUNCIONAMIENTO CON AIRE SECO 55 ACESSÓRIOS 61 PRECAUÇÕES DE SEGURANÇA 61 NOME DAS PEÇAS 63 NOME E FUNÇÕES DOS INDICADORES E CONTROLOS 63 NOME E OPERAÇÕES DOS INDICADORES E CONTROLOS 64 ...

Page 4: ...ce person and not for the customer Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health When you notice something abnormal with the air conditioner smells like some thing scorching poor cooling etc immediately turn off the main switch the circuit breaker from the mains to stop the air conditioner and contact the dealer If the air c...

Page 5: ...the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is used in a closed room be careful of sufficient ventilation of the room Poor ventilation causes oxygen shortage Do not touch any switches with wet finger otherwise you may...

Page 6: ...n operation the OPERATION lamp is orange TEMPORARY button If you misplace or lose the remote controller or its batteries are exhausted push the TEMPORARY button 1 Open the air inlet grille to push theTEMPORARY button 2 Push the TEMPORARY button to start the air conditioner Push this button once again to stop it 3 Continue to push the button for 10 seconds to start cooling operation Preparing the f...

Page 7: ...set up temp display section 4 Operation mode display The selected operation mode is displayed 5 Fan mode display The selected fan mode is displayed LOW MED HIGH 6 Air volume fix display This is not displayed on this model 7 CENTRAL control display Displayed when used with the central remote controller etc 8 STANDBY display It is displayed when the operation cannot be performed though it is not an ...

Page 8: ...ual attached to each remote controller 1 Operation select button Selects desired operation mode 2 Air volume select button Selects the desired air volume mode 3 Set up temp button Adjusts the required room temperature Match to the desired set temperature by pushing 4 Filter reset button Resets Erases FILTER display 5 CHECK button When an error fault occurs on the air conditioner this button is use...

Page 9: ...ation mode with MODE button For every push of the button the display changes as right figure 2 Select air volume with the FAN button The display changes as follows LOW MED HIGH AUTO When air volume is AUTO air volume changes according to the room temperature 3 Determine the set up temperature by pushing the TEMP button 4 Push ON OFF button The operation lamp goes on and the operation starts STOP P...

Page 10: ...lly select either cooling heating or fan only operation depending on the outdoor temperature Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select Auto 3 Temperature button Set the desired temperature In case of cooling it starts the operation after approx 1 minute In case of heating the operation mode is selected in accordance with the room tempe...

Page 11: ... louver manually Always use the LOUVER button If you move the louver manually it may malfuction during operation If the louver malfunctions stop the air conditioner once and restart Adjust the horizontal air flow Preparation Take hold of the lever on the horizontal air flow louver and move them to adjust the air flow direction as you desire You can adjust the air flow at the left center and right ...

Page 12: ... The lamp will start to indicate after every 1000 hours of operation The FILTER lamp will be out when the TEMPORARY button is pushed The FILTER lamp will also be out when the FILTER button on the remote controller is pushed MAINTENANCE WARNING Before you clean the air conditioner be sure to turn off the circuit breaker or main power switch Cleaning of indoor unit and remote controller CAUTION Use ...

Page 13: ...left and right handles of the air filter and lift it up slightly then pull it downward to take it out from the filter holder 3 Remove the filters 4 Use a vacuum cleaner to remove the dust from the filters or wash them with water If you wash the air filters dry them in the shade Filter holder Filter holder Air filter 5 Insert the upper portion of the air filter aligning right and left edges on the ...

Page 14: ...ille is completely closed AIR CONDITIONER OPERATIONS AND PERFORMANCE 3 minute protection function A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is turned on This will protect the machine Heating operation characteristics Preheating operation The air conditioner will...

Page 15: ...Room temperature Less than 30 C PROBLEMS AND CAUSES CAUTION If any of the following conditions occur turn off the main power supply switch and immediately contact the dealer The indicator lamps flash at short intervals 5 Hz even though you have tried turning off the power supply and turning on again after 2 to 3 minutes Switch operation is erratic The main power fuse often blows out or the circuit...

Page 16: ...1075000645 ...

Reviews: