Concealed Duct High Static Pressure

Owner’s Manual

CAUTION

TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY

• This appliance must be connected to the mains by means of a switch with a contact separation of at least 

3 mm

.

The installation fuse 25A must be used for the power supply line of this air conditioner.

CAUTIONS ABOUT INSTALLATION (Be sure to confirm the following cautions.)

• Certainly lay the drain hose for perfect draining.

Bad drainage may cause flooding in the house and getting furniture wet.

• Make sure to connect the air conditioner to an exclusive power supply of the 

rated voltage, otherwise the unit may break down or cause a fire.

• Do not install the unit in a place where inflammable gas may leak.

If inflammable gas accumulates around the unit, it may cause a fire.

CAUTIONS ABOUT OPERATION

• Carefully read this manual before starting the air conditioner.

There are many important things to keep in mind for daily operation.

• Do not use this air conditioner for special purpose such as preserving food, 

precision instruments, art objects, breeding animals, car, vessel, etc.

• When the air conditioner is operated with a combustion appliance in the same 

place, be careful of ventilation to let fresh air enter the room.
Poor ventilation causes oxygen shortage.

• Do not place any combustion appliance in a place where it is directly exposed 

to the wind of air conditioner, otherwise it may cause imperfect combustion.

• When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. 

Poor ventilation causes oxygen shortage.

• Do not touch any switches with wet finger, otherwise you may get an electric shock.

• If the air conditioner won’t be used for a considerably long time, turn off the main switch or the circuit 

breaker, for safety.

• Do not put anything on the outdoor unit nor step onto it. 

If you do so, it may not only topple over the unit but also injure yourself.

• To make the air conditioner operate in its original performance, operate it within the range of the operating 

temperature specified in the instructions.
Otherwise it may cause a malfunction, or water leak from the unit.

• Prevent any liquid from falling into the remote controller. 

Do not spill juice, water or any kind of liquid.

3-EN

+00EH99931901_01EN_Ducthigh_OM.book  Page 3  Tuesday, April 8, 2008  10:33 AM

Summary of Contents for RAV-SM1403DT-A

Page 1: ...ONER SPLIT TYPE Indoor Unit Model name Concealed Duct High Static Pressure Type RAV SM1403DT A RAV SM1603DT A Owner s Manual Not accessible to the general public 00EH99931901_01EN_Ducthigh_OM book Page 1 Tuesday April 8 2008 10 33 AM ...

Page 2: ... Thank you very much for purchasing TOSHIBA Air Conditioner Please read this owner s manual carefully before using your Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual and hand over it ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which...

Page 3: ... person do it Do not attempt it yourself Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health When you notice something abnormal with the air conditioner smells like something scorching poor cooling etc immediately turn off the main switch the circuit breaker from the mains to stop the air conditioner and contact the dealer If the ...

Page 4: ...t objects breeding animals car vessel etc When the air conditioner is operated with a combustion appliance in the same place be careful of ventilation to let fresh air enter the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner...

Page 5: ...R SET TEST FILTER RESET CL FAN SAVE SWING FIX VENT MODE UNIT LOUVER Remote controller Separate sold part Air heat exchanger Air inlet Connect a suction duct Drain pan Drain pipe connector Refrigerant pipe connector Power input Electric parts box The earth screw is provided in the electric parts box Air inlet Side and rear Air outlet Pipes and electric wires 4 EN 00EH99931901_01EN_Ducthigh_OM book ...

Page 6: ... Timer time display Time of the timer is displayed When a trouble occurs the check code is displayed 5 Timer SET IN setup display When pushing the Timer SET IN button the display of the timer is selected in order of OFF OFF repeat OFF timer ON No display 6 Filter display If FILTER is displayed clean the air filter 7 TEST run display Displayed during a test run 8 Set up temperature display The sele...

Page 7: ...ntral control display Displayed when the air conditioner is used under the central control in combination with a central control remote controller In case the remote controller is disabled by the central control system flashes The button operation is not accepted Even when you push ON OFF MODE or TEMP button and the button operation is not accepted Settings made by the remote controller vary with ...

Page 8: ...unction 8 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it flashes when operating the protection device or abnormal time 9 button When the button is pushed the operation starts and it stops by pushing the button again When the operation has stopped the operation lamp and all the displays disappear 10 button Operation select button Selects desired operation mode ...

Page 9: ...1 Push button The operation lamp goes on and the operation starts 2 Select an operation mode with the MODE button One push of the button and the display changes in the order shown as follows 3 Select air volume with button One push of the button and the display changes in the order shown as follows When air volume is AUTO air volume differs according to the room temperature In heating operation if...

Page 10: ...he installer or dealer for the settings according to the installation manual of the indoor unit Start Stop NOTE The discharged air temperature is lower than that in the normal heating operation The room temperature may not be heated evenly depending on the remote controller installation location The room temperature may not reach 8 C depending on the room size or the installation conditions The ai...

Page 11: ...ours 2 3 Push SET button display disappears and timer time display goes on and or display flashes When ON timer is activated timer time ON timer are displayed and other displays disappear 4 Cancel of timer operation Push button TIMER display disappears NOTE When the operation stops after the timer reached the preset time the Repeat OFF timer resumes the operation by pushing button and stops the op...

Page 12: ...mode to save energy as well Power saving mode consumes less energy but may not heat cool the room as much as normal mode The maximum current is limited of the normal mode To adjust the power save settings see How to set up power saving mode in ADVANCED SETTINGS When the power saving operation is performed with a Digital Inverter outdoor unit the power saving rate in the actual operation is 75 Even...

Page 13: ... numbers change as follows The fan of the selected unit runs 3 Adjust the power save setting by pushing TIME buttons Each push of the button changes the power level by 1 within the range from 100 to 50 The factory setting is 75 This indication may not be true for types other than Digital Inverter outdoor unit 4 Push button 5 Push button to complete the setting 4 3 1 5 2 UnitNo 1 1 UnitNo 1 2 UnitN...

Page 14: ...ation lamp and on the remote controller flash When the protective device is activated When the protective device has been activated and stopped operation turn off the leakage breaker immediately and ask the installer to find the cause If the air conditioner is operated without fixing the problem the air conditioner may malfunction Check whether the air filters are installed If the air filters are ...

Page 15: ...r long It may damage or fade the surface of the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Periodic check Long period use of the air conditioner may cause deterioration or failure of parts due to heat humidity dust and operating conditions or may cause poor drainage of dehumidified water If you do not pla...

Page 16: ...mance freezing water leakage and even compressor failure Maintenance List Part Unit Check visual auditory Maintenance Heat exchanger Indoor outdoor Dust dirt clogging scratches Wash the heat exchanger when it is clogged Fan motor Indoor outdoor Sound Take appropriate measures when abnormal sound is generated Filter Indoor Dust dirt breakage Wash the filter with water when it is contaminated Replac...

Page 17: ...defrosting operation During the defrosting operation the defrosted water will be drained from the bottom plate of the outdoor unit Heating capacity In the heating operation the heat is absorbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the a...

Page 18: ...o use the rated voltage and an exclusive circuit for power supply of the air conditioner Do not install the air conditioner in the following places Do not install the air conditioner in any place within 1 m from a TV stereo or radio set If the unit is installed in such place noise transmitted from the air conditioner affects the operation of these appliances Do not install the air conditioner near...

Page 19: ...ts that are not operating WARNING Re Installation Ask the dealer or an installation professional to re install the air conditioner to a new place or move it to another place and to observe the following items If the air conditioner is inappropriately installed by yourself it may cause electric shock or fire 12TROUBLES AND CAUSES CAUTION If any of the following conditions occur turn off the main po...

Page 20: ...both the indoor and outdoor units stop air flow Hiss sound is heard when flow of the refrigerant is changed for defrosting Resultant water of automatic defrosting in heating operation drains from outdoor unit Air flow changes though the FAN button is not set to the AUTO mode When the temperature of blown air drops in heating operation the air conditioner automatically changes or stops air flow fro...

Page 21: ...Toshiba XXXXXXX X X 20 Concealed Duct High Static Pressure Owner s Manual EN 20 EN 00EH99931901_01EN_Ducthigh_OM book Page 20 Tuesday April 8 2008 10 33 AM ...

Page 22: ...er TOSHIBA CARRIER CORPORATION Address city country 23 17 Takanawa 3 Chome Minatoku Tokyo 108 0074 Japan Name of the Importer Distributor in EU CARRIER CORPORATION Address city country Via Raffaello Sanzio 9 20058 Villasanta MI Italy 00EH99931901_01EN_Ducthigh_OM book Page 21 Tuesday April 8 2008 10 33 AM ...

Reviews: