TIMER OPERATION
• Three timer modes are available: (Setting of up to 168 hours is enabled.)
Set
1
Push
button.
The timer mode changes with every push of the
button.
•
and timer display flashes.
2
Push
to select “set time”.
• With every push of
button, the set time
increases by 0.5 hr (30 minutes).
When setting a time more than 24 hours for
timer operation, timer can be set in increments
of 1 hr.
The maximum set time is 168hr (7 days).
The remote controller displays the set time with
time (between 0.5 and 23.5 hours) (*
1
) or
number of days and time (24 hours or more) (*
2
)
as shown below.
• With every push of
button, the set time
decreases by 0.5 hr (30 minutes) (0.5 -
23.5 hours) or 1 hr (24 - 168 hours).
Example of remote controller display
• 23.5 hours (*
1
)
• 34 hours (*
2
)
3
Push
button.
•
icon disappears and time display goes
on, and
or
icon flashes.
(When ON timer is activated, time and ON timer
are displayed and other icons
disappear.)
4
Cancel timer operation
Push
button.
Timer icon disappears.
NOTE
• When the operation stops after the timer reached
the preset time, the Repeat OFF timer resumes the
operation by pushing
button and stops the
operation after the time of the timer has reached the
set time.
• When you push
while the OFF timer function
of the air conditioner is active, the indication of the
timer function disappears and then appears again
after about 5 seconds
.
This is due to normal processing of the remote
controller.
OFF timer
: The unit stops when the set time is reached.
Repeat OFF timer : The unit stops daily when the set time is reached.
ON timer
: The unit starts when the set time is reached.
1
3
2
4
shows 1 day (24 hours).
shows 10 hours. (Total 34 hours)
(OFF timer)
(ON timer)
(Repeat OFF timer)
No display
OFF
OFF
ON
Number of days Time
11-EN