10
EN
Engineering Data
1-1-9.
Indoor unit (Compact 4-way Cassette (600 × 600) Type)
<Double twin type>
* IEC standard
Model
Indoor unit 1
RAV-SM562MUT-E
RAV-SM562MUT-E
Indoor unit 2
RAV-SM562MUT-E
RAV-SM562MUT-E
Indoor unit 3
RAV-SM562MUT-E
RAV-SM562MUT-E
Indoor unit 4
RAV-SM562MUT-E
RAV-SM562MUT-E
Outdoor unit
RAV-SM2244AT8-E
RAV-SM2244AT7
Cooling capacity (min. - max.)
(kW)
20.0 (9.8-22.4)
20.0 (9.8-22.4)
Heating capacity (min. - max.)
(kW)
22.4 (9.8-25.0)
22.4 (9.8-25.0)
Power supply
3 phase 380-415V 50Hz
3 phase 380V 60Hz
Indoor unit
Electrical
characteristics
Cooling
Running current
(A)
11.51 - 10.54
11.51
Power consumption (min. - max.)
(kW)
7.12 (2.37-9.28)
7.12 (2.37-9.28)
Power factor
(%)
94
94
EER
2.81
2.81
Energy efficiency class *
C
C
Heating
Running current
(A)
10.34 - 9.47
10.34
Power consumption (min. - max.)
(kW)
6.40 (1.98-7.46)
6.40 (1.98-7.46)
Power factor
(%)
94
94
COP
3.50
3.50
Energy efficiency class *
B
B
Maximum current
(A)
18
18
Fan unit
Fan
Turbo fan
Turbo fan
Standard air flow H/M/L
(m3/min)
13.3/11.2/9.1
13.3/11.2/9.1
Motor
(W)
60
60
Sound pressure level
H/M/L
(dB/A)
43/39/34
43/39/34
Sound power level
H/M/L
(dB/A)
58/54/49
58/54/49
Outdoor unit
Outer dimension
Max. total length
(m)
70
70
Min. length
(m)
7.5
7.5
Height difference
Outdoor lower
(m)
30
30
Outdoor high
(m)
30
30
Fan unit
Fan
Propeller fan
Propeller fan
Standard air flow high
(m3/min)
133
133
Motor
(W)
100 + 100
100 + 100
Connecting pipe
Outdoor unit -
First pipe branch
Gas side
(mm)
28.6
28.6
Liquid side
(mm)
12.7
12.7
First pipe branch -
Second pipe branch
Gas side
(mm)
15.9
15.9
Liquid side
(mm)
9.5
9.5
Second pipe branch -
Indoor unit
Gas side
(mm)
12.7
12.7
Liquid side
(mm)
6.4
6.4
Sound pressure level
Cooling/Heating
(dB/A)
56/57
56/57
Sound power level
Cooling/Heating
(dB/A)
72/74