Toshiba RAV-HM1101UTP-E Owner'S Manual Download Page 12

22-EN

21-EN

– 11 –

5

Self clean mode

This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling
/ dry / AUTO (cooling) mode to keep the indoor unit clean.

•   

The self clean time varies with the cooling / dry / Auto (cooling) operation time as follows.

Cooling / dry / Auto (cooling) operation time

self clean time

Less than 10 minutes

No self clean operation

10 minutes to less than 1 hour

1 hour

More than 1 hour

2 hours

•   

 ” is displayed on the remote controller during self clean operation.

To stop self clean forcibly, push 

 button twice in succession.

 

CAUTION

•   

The fan continues to run even after

 

 

button is pushed to stop operation in some modes.

This is normal because the self clean mode is in progress.

•   

The louvers open slightly and are directed horizontally during self clean, and they close when the self clean is 
completed.

•   

The operation lamp (LED) does not light during the self clean mode (function).

•   

The self clean mode (function) cannot clean the room or remove the already existing mold and dust inside the indoor
unit.

•   

To cancel the self clean function, consult the dealer.

6

Maintenance

 

WARNING

Cleaning the air 

fi

 lter and other parts of the air 

fi

 lter involves dangerous work in high places, so be sure 

to have a quali

fi

 ed installer or quali

fi

 ed service person to do it.

Do not attempt it by yourself.

 

CAUTION

Do not push buttons with wet hands.

Doing so may result in electric shock.

Cleaning the air 

fi

 lters

•   

When the 

fi

lter indicator is displayed on the remote controller, clean the air 

fi

lters.

(Only for RBC-AMTU*** and RBC-AMSU*** remote controllers.)

•  Clogged 

fi

lters may lower the cooling and heating performance.

When the unit will not be used for a long time

1. Perform the fan operation for a couple of hours to dry inside.
2. Stop the air conditioner with the remote controller and turn off the circuit breaker.
3. Clean the air 

fi

 lters and reinstall them.

Before the cooling season

Clean the drain pan

•   

Contact the dealer where you purchased the product.
(Drain does not work if the drain pan or vent is clogged. In some cases the drain may over

fl

ow and wet the wall or 

fl

oor. 

Be sure to clean the drain pan before the cooling season.)

Summary of Contents for RAV-HM1101UTP-E

Page 1: ... CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name For commercial use English R32 4 way Cassette Type RAV HM561UTP E RAV HM801UTP E RAV HM901UTP E RAV HM1101UTP E RAV HM1401UTP E RAV HM1601UTP E ...

Page 2: ...uced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory o...

Page 3: ...alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by th...

Page 4: ... industry or for commercial use by lay persons Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Warning indications on the air conditioner unit Warning indication Des...

Page 5: ...rthing is performed correctly Operation Before opening the intake grille of the indoor unit or service panel of the outdoor unit set the circuit breaker to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the intake grille of t...

Page 6: ...ition and contact a qualified service person Take steps to ensure that the power will not be turned on by marking out of service near the circuit breaker for instance until qualified service person arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan grille is damaged do not approach t...

Page 7: ...unction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and caus...

Page 8: ...e out of pallet when stacking Lay a 10 mm thick plywood over the pallet 2 Part names Indoor unit Projection of air filter Discharge louver of discharge port Change the direction of the air to be discharged according to cool heat mode Suction air port The air in the room is sucked in from this port Earth screw Provided in the electrical control box Knob Knob to open close the suction port Air filte...

Page 9: ...r central control devices If the central control prohibits using the remote controller will flash when pressing the ON OFF mode or temperature button on the remote controller indicating that these buttons do not work The settings that can be configured on the remote controller will vary depending on the central control mode For details please read the Owner s Manual of the central remote controlle...

Page 10: ...time then the running mode and its icons change in the following order Auto Dehumidify Heat Dry Cool Fan Dehumidify is not available for concealed duct high static press type If the button is not operated within 30 seconds the running mode selection will end 3 Select the fan speed Switch to the fan speed mode by pressing the menu button The current fan speed icon flickers Press the set button each...

Page 11: ...itions Setting for fan speed is available during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this op...

Page 12: ...om or remove the already existing mold and dust inside the indoor unit To cancel the self clean function consult the dealer 6 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places so be sure to have a qualified installer or qualified service person to do it Do not attempt it by yourself CAUTION Do not push buttons with wet hands Doing ...

Page 13: ...itioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when an indoor unit is operated for 8 hours or more daily clean the indoor unit and outdoor unit at least once every 3 months Ask a professional fo...

Page 14: ...ge of the outdoor unit are often covered with snow or frozen up If snow or freeze on the outdoor unit is left as it is it may cause machine failure or poor warming In cold areas pay attention to the drain hose so that it perfectly drains water without water remaining inside for freeze prevention If water freezes in the drain hose or inside the outdoor unit it may cause machine failure or poor warm...

Page 15: ...ace where sulfureous gas generated such as in a spa Do not install the air conditioner in a vessel or mobile crane Do not install the air conditioner in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the aluminum fin and copper pipe of the heat exchanger Do not install the air conditioner...

Page 16: ... becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Industrial Estate Roborough Plymouth Devon PL6 7DB United...

Page 17: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115350295 ...

Reviews: