6. REFRIGERANT PIPING DIAGRAM
Outdoor unit
Model
RAV-363A8-PE
RAV-463A8-PE
Capillary
IDø2.4 x 500L x 1P
IDø2.6 x 700L x 1P
Outdoor Unit
TC sensor
Refrigerant pipe (Large side)
ø 19 mm
Distributor
strainer
Refrigerant pipe (Small side)
ø 9.5 mm
Packed valve
Heat exchanger
Packed valve
Strainer
Accumulator
Heat exchanger
Capillary tube
Capillary tube
Pressure switch
Dryer
Compressor
Strainer
Indoor unit
Outdoor unit
RAV-362B-PE
RAV-363A8-PE
RAV-362C-PE
RAV-363A8-PE
RAV-362U-PE
RAV-363A8-PE
RAV-462B-PE
RAV-463A8-PE
RAV-462C-PE
RAV-463A8-PE
RAV-462U-PE
RAV-463A8-PE
Capillary
IDø2.0 x 400L x 6P
IDø2.0 x 300L x 7P
IDø2.0 x 300L x 8P
IDø2.2 x 200L x 6P
IDø2.0 x 200L x 8P
IDø2.0 x 300L x 8P
Model
RAV-362B-PE
RAV-362C-PE
RAV-362U-PE
RAV-462B-PE
RAV-462C-PE
RAV-462U-PE
Indoor Unit
Indoor unit
Check Joint
Bimetal Thermostat