![Toshiba RAS-M22SKV-E Service Manual Download Page 66](http://html.mh-extra.com/html/toshiba/ras-m22skv-e/ras-m22skv-e_service-manual_1135164066.webp)
11-
8
-3. Indoor Unit (Other Parts)
11-
8
-4. Outdoor Unit
5
4
3
2
1
White
Yellow
Yellow
Yellow
Yellow
5
4
3
2
1
No.
1
2
3
4
Part name
Room temp. (TA) sensor
Heat exchanger (TC) sensor
Remote controller
Louver motor
MP24Z3T
Indoor fan motor
Checking procedure
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
Refer to 11-5-1. (3) and (4).
Temperature
Sensor
TA, TC (k
Ω
)
10°C
20°C
25°C
30°C
40°C
20.7
12.6
10.0
7.9
4.5
Position
1 to 2
1 to 3
1 to 4
1 to 5
Resistance value
250 ± 20
Ω
Refer to SERVICE MANUAL of connected outdoor unit.
– 85 –
11-
8
-5. Checking Method for Each Part
MCC-5009
Soldered
surface
Heat sink IGBT side
C12
C13
C14
Resistance value
in good product
∞
Tester rod
+
–
~
2
~
3
~
2
~
3
–
4
~
~
~
+
–
~
1
1 2 3
(DBO1)
4
4
2
3
+
1
+
–
No.
1
2
Part name
Electrolytic capacitor
(For boost, smoothing)
Diode block
Checking procedure
1. Turn OFF the power supply breaker.
2. Discharge all three capacitors completely.
3. Check that safety valve at the bottom of capacitor is not broken.
4. Check that vessel is not swollen or exploded.
5. Check that electrolytic liquid does not blow off.
6. Check that the normal charging characteristics are shown in continuity test by the
tester.
Case that product is good
Pointer swings once, and returns slowly.
When performing test once again under
another polarity, the pointer should return.
C12, C13, C14
→
18SAV-E: 500µF/400V, 22SAV-E: 760µF/400V
1. Turn OFF the power supply breaker.
2. Completely discharge the four electrolytic capacitors.
3. Remove the diode block from the P.C. board (which is soldered in place).
4. Use a multimeter with a pointer to test the continuity, and check that the diode
block has the proper rectification characteristics.
10 to 20
Ω
when the multimeter probe is
reversed
11-
9
. How to Simply Judge Whether Outdoor Fan Motor is Good or Bad
Refer to SERVICE MANUAL of connected outdoor unit.
–
66
–