• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.
2-1.
Specifications
<Heat Pump Models>
RAS-5M34S3AV-E, -A, -TR
Unit model
RAS-
Outdoor
RAS-
Cooling Capacity
(kW)
Cooling Capacity range
(kW)
Heating Capacity
(kW)
Heating Capacity range
(kW)
Power supply
Electric
characteristics
Operation mode
Total
Running current
(A)
Power consumption
(W)
Power factor
(%)
Starting current
(A)
COP
(Cooling/Heating)
Operating noise
Outdoor
Full indoor units operating
(Cooling/Heating)
Height
(mm)
Dimension
Width
(mm)
Depth
(mm)
Net weight
(kg)
Outdoor unit
Motor output
(W)
Compressor
Type
Model
Fan motor output
(W)
Air flow rate
(m³/h)
Type
A unit liquid side/gas side
Outdoor unit
B unit liquid side/gas side
C unit liquid side/gas side
Piping connection
D unit liquid side/gas side
E unit liquid side/gas side
Maximum length (per unit)
(m)
Maximum length (total)
(m)
Maximum chargeless length
(m)
Maximum height difference
(m)
Name of refirigerant
Weight
(kg)
Wiring connection
Power supply
/
interconnection
Usable temperature range
Outdoor
(Cooling/Heating)
(°C)
Accessory
Outdoor unit
Unit model
RAS-
Installation manual
B13N3KV2-E1 (X5)
5M34
S3AV-E, -A, -TR
10.0
3.7
to 11.0
12.0
2.7
to 14.0
220-240V 1Ph 50Hz / 220V 1Ph 60Hz
Cooling
Heating
14.26 / 13.65 / 13.07
13.56 / 12.97 / 12.43
29
80
2833
95
95
14.26 / 13.65 / 13.07
3.
36
/ 4.24
5
2
/ 5
5
890
900
320
7
8
2200
Twin rotary type with DC-inverter variable speed control
DA270A
2T
-20L
D
100
High: 3666, Medium: 2800
Flare connection
Ø6.35 / Ø12.7
Ø6.35 / Ø12.7
Ø6.35 / Ø9.52
Ø6.35 / Ø9.52
Ø6.35 / Ø9.52
25
80
40
15
R410A
2.99
3 Wires : includes earth
/
4 Wires : includes earth
-1
0
to
4
6
/ -1
5
to
2
4
5M34
S3AV-E, -A, -TR
1
2. SPECIFICATIONS
The indoor and outdoor units that can be used in combination are shown in the tables below.
NOTES
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit).
Be sure to connect indoor units in two or more.
CAUTION
• Exposure of unit to water or other moisture before installation may result in an electrical short.
Do not store in a wet basement or expose to rain or water.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify
the noise level of the unit or where noise or discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Perform the specified installation work to guard against an earthquake.
If the air conditioner is not installed appropriately, accidents may occur due to the falling unit.
Heat pump
RAS-5M34S3AV-E,
-A,
-TR
Table of models that can be used in combination
Type
Outdoor unit
Combinations of indoor unit models that can be connected
Refer to page 8 to 25
FILE NO. SVM-15036
- 5 -
Summary of Contents for RAS-5M34S3AV-A