background image

Set your preferred operation for future use. The setting will be memorized by the 
unit for future operation (except airfl ow direction).
  1.  Select your preferred operation.

 2. 

 

Press and hold 

 for 3 seconds to memorize the setting. 

The 

P

 mark displays.

 3. 

Press 

 : Operate the preset operation.

To automatically restart the air conditioner after the power failure (Power of the 
unit must be on.)

Setting

1.  Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds)

2.  Press and hold the RESET button on the indoor unit for 3 seconds to cancel 

the operation. (3 beep sound but OPERATION lamp does not blink)

 

•  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
  does not activate.

To operate at super low fan speed for quiet operation (except in DRY mode)

 Press 

QUIET

 : Start and stop the operation.

 Note: 

Under certain conditions, QUIET operation may not provide adequate  

  cooling due to low sound features.

For comfortable sleep, automatically control air fl ow and automatically turn OFF.

 Press 

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

 Note: 

The cooling operation, the set temperature will increase automatically 

  1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
  operation, the set temperature will decrease.

 Firstly, turn off the circuit breaker.

Filter Reset (Some models only)

FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.

Indoor Unit and Remote Control

•   Clean the indoor unit and the remote control with a wet cloth when needed. 
•   No benzine, thinner, polishing powder or chemically-treated duster.

 

1.   Three-minute protection feature: To prevent the unit from being activated   
 

for 3 minutes when suddenly restarted or switched to ON.

 

2.  Preheating operation: Warm up the unit for 5 minutes before blowing warm air.

 

3.  Warm air control: When the room temperature reaches the set temperature, 
 

the fan speed is automatically reduced and the outdoor unit will stop.

 

4.  Automatic defrosting: Fans will stop during defrost operation.

 

5.  Heating capacity: Heat is absorbed from outdoor and released into the room.
 

When the outdoor temperature is too low, use another recommended heating

 

apparatus in combination with the air conditioner.

 

6.  Consideration for accumulated snow: Select the position for outdoor unit where
 

it will not be subjected to snow drifts, accumulation of leaves or other seasonal

 debris.

 

7.  Some minor cracking sound may occur when unit operating. This is normal
 

because the cracking sound may be caused by expansion/contraction of

 plastic.

 

Note:

 Item 2 to 6 for Heating model

Air conditioner operating conditions

To protect bad smell caused by the humidity in the indoor unit.

1. If the 

 button is pressed once during “Cool” or “Dry” mode, 

 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

2.  To stop the unit immediately, press the 

 more 2 times within 

30 seconds.

Temp. 

Operation

Outdoor Temperature

Room

Temperature

Heating

–15°C ~ 24°C

Less than 28°C

Cooling

–10°C ~ 46°C

21°C ~ 32°C

Dry

–10°C ~ 46°C

17°C ~ 32°C

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON. 
2.  Point the remote control at the indoor unit.
3.  Push and hold 

 button on the Remote Control by the tip of the pencil.

   “00” will be shown on the display.

4.  Press 

 during pushing 

. “B” will show on the display and “00” 

will disappear and the air conditioner will turn OFF. The Remote Control B 
is memorized.

Note: 

1.  Repeat above step to reset Remote Control to be A.

   

2.  Remote Control A has not “A” display.

   

3.  Default setting of Remote Control from 

factory is A.

The unit does not operate.

Cooling or Heating is abnormally low.

•   The power main switch is turned 

off. 

•   The circuit breaker is activated to 

cut off the power supply. 

•   Stoppage of electric current. 
•   ON timer is set. 

•   The fi lters are blocked with dust.
•   The temperature has been set 

improperly.

•   The windows or doors are opened.
•   The air inlet or outlet of the outdoor 

unit is blocked.

•   The fan speed is too low.
•   The operation mode is FAN or DRY.

OPERATION AND PERFORMANCE

19

TROUBLESHOOTING (CHECK POINT)

20

REMOTE CONTROL A-B SELECTION

21

PRESET OPERATION

13

AUTO RESTART OPERATION

14

QUIET OPERATION

15

COMFORT SLEEP OPERATION

16

MAINTENANCE

17

SELF CLEANING OPERATION (COOL AND  

 

DRY OPERATION ONLY)

18

TSB_1110655143_EN.indb   4

TSB_1110655143_EN.indb   4

12/8/14   2:35 PM

12/8/14   2:35 PM

Summary of Contents for RAS-22N3AV2-A

Page 1: ...PE For general public use Indoor unit RAS 10 13 16 18 22 24N3KV2 A1 Outdoor unit RAS 10N3AV2 A1 RAS 13 16 18 22N3AV2 A OWNER S MANUAL 1110655143 TSB_1110655143_EN indb 1 TSB_1110655143_EN indb 1 12 8 14 2 38 PM 12 8 14 2 38 PM ...

Page 2: ... Otherwise abnormally high pressure may be generated in the refrigeration cycle which may result in a failure or explosion of the product or an injury to your body 1 Hi POWER Green 2 FILTER Orange 3 PRE DEF Preheat Defrost Orange 4 TIMER Yellow 5 OPERATION Green 6 RESET button CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly installed it may caus...

Page 3: ...e operation To automatically select cooling heating or fan only operation 1 Press MODE Select A 2 Press Set the desired temperature 3 Press FAN Select AUTO LOW LOW MED MED or HIGH 1 Press MODE Select Cool Heat or Fan only 2 Press Set the desired temperature Cooling Min 17 C Heating Max 30 C Fan Only No temperature indication 3 Press FAN Select AUTO LOW LOW MED MED or HIGH For dehumidification a mo...

Page 4: ...hen the outdoor temperature is too low use another recommended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris 7 Some minor cracking sound may occur when unit operating This is normal because the cracking sound may be caus...

Page 5: ...MEMO TSB_1110655143_EN indb 5 TSB_1110655143_EN indb 5 12 8 14 2 35 PM 12 8 14 2 35 PM ...

Page 6: ...MEMO TSB_1110655143_EN indb 6 TSB_1110655143_EN indb 6 12 8 14 2 35 PM 12 8 14 2 35 PM ...

Page 7: ...TSB_1110655143_EN indb 7 TSB_1110655143_EN indb 7 12 8 14 2 35 PM 12 8 14 2 35 PM ...

Page 8: ...1110655143 TSB_1110655143_EN indb 8 TSB_1110655143_EN indb 8 12 8 14 2 35 PM 12 8 14 2 35 PM ...

Reviews: