10-5-
2
.
Power Supply and Connecting Cable Connection
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor unit
Outdoor unit
Power supply cable
Power supply cable
connect to
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Stripping length of the power
supply cable
Earth line
50 mm
10 mm
10 mm
70 mm
Connecting
cable
Terminal block
Earth line
Connecting cable
RAS-05, 07, 10, 13TAVG-EE
Connecting
cable
Terminal block
Earth line
Connecting cable
RAS-16, 18TAVG-EE
Connecting cable
Earth line
Earth line
Power supply
cable
Terminal block (L N 1 2 3)
Connecting cable
connect to
Connecting
cable
Stripping length of the
connecting cable
Earth line
70 mm
10 mm
10 mm
50 mm
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor unit
Outdoor unit
Connecting cable
Connecting cable
connect to
Terminal block (L N 1 2 3)
Earth line
Connecting cable
Stripping length of the
connecting cable
Earth line
70 mm
10 mm
10 mm
50 mm
Connecting cable
Power cord
Terminal block
Earth line
Connecting cable
Earth line
Power cord
RAS-05, 07, 10, 13TAVG-EE
Connecting cable
Power cord
Terminal block
Connecting cable
Earth line
Earth line
Power cord
RAS-16, 18TAVG-EE
FILE NO. SVM-19040
- 71 -