
−
18
−
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
Reactor
L = 10mH, 16A
2
Outdoor fan motor
DC140V, 43W
3
Suction temp. sensor (TS sensor)
10k
Ω
(25°C)
4
Discharge temp. sensor (TD sensor)
62k
Ω
(20°C)
5
Outside air temp. sensor (TO sensor)
10k
Ω
(25°C)
6
Heat exchanger temp. sensor (TE sensor)
10k
Ω
(25°C)
7
Terminal block (5P)
30A, AC600V
9
COIL FOR P.M.V.
DC12V
10 Coil for 4-way valve
AC220-240V
CAM-MD12TCTH-5
SQ
Compressor
3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA108X1C-23FZ
Parts name
Model name
Rating
CH-57 x 2 PCS
ICF-140-43-4R
FILE NO. SVM-13027
No.
Parts name
Type
Specifications
ICE
-
3
40-
30-4
D
C
3
40V,
3
0W
2 Room temp. sensor (TA-sensor)
( - )
10k
Ω
at 25
°
C
3 Heat exchanger temp. sensor (TC-sensor)
( - )
10k
Ω
at 25°C
4 Louver motor
24BYJ48-HTP Output (Rated) 1W, 16 poles, DC12V
1
Fan motor (for indoor)