7
-
4.
SPECIFICATION OF ELECTRICAL PARTS
4-1.
Indoor Unit
4-2.
Outdoor Unit
FILE NO. SVM-08029
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) AFS- 220-20-4AR
AC Motor with 145 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Transformer
4 Microcontroller unit (IC30) TMP87CM40ANG
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-06270
27mH, 600mA
7 Bridge rectifier (DB01) DB105G 1.0A, 600 V
8 Capacitor (C27) EKMH401VSN470MP20S 47
m
F, 400 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R
62
, R
63
)
SR561K14DL
560 V
1
1
Louver motor MP24
Z3T
12VDC
1
2
Relay (Comp., RY01)
G4A-1A
Rating 2
5
A/A
C250V
W
°
°
°
W
ST-001
No.
Parts name
Type
Specifications
Output (Rated) 990 W, 2 poles, 1 phase, 220
-
240 V, 50Hz
1 Compressor QK222PCB Winding resistance (
W
) C-R C-S
(at 25 C) 2.67 3.92
Output (Rated) 30 W, 6 poles, 1 phase, 220
-
240 V, 50Hz
2 Fan motor (for outdoor)
Winding resistance (
W
) Red-Black White-Black
(at 20 C) 237 380
3
Running capacitor
DS451155NPQB AC 450 V, 1.5
µ
°
°
4
Running capacitor
RS44B356U0125S AC 440 V, 35 F
(for compressor)
m
WLF-240-30A
F
5
Overload relay
LAAO00A U/T : 9.0A (80°C), Open : 135±5°C, Close : 75±11°C