– 5 –
FILE NO. SVM-03004(1)
MODEL
RAS-13UKPX2 / RAS-13UAX2
RAS-10UKPX2 / RAS-10UAX2
ITEM
Cooling
Capacity
220 V
240 V
220 V
240 V
kW
3.70
3.75
2.65
2.70
Phase
1
∅
Power source
V
220 – 240
Hz
50
Power consumption
kW
1.24
1.28
0.80
0.85
Power factor
%
98
95
97
95
Running
Indoor
A
0.15
current
Outdoor
A
5.60
5.45
3.60
3.58
Starting current
A
24
16
Moisture removal
lit/h
2.0
1.2
Noise
Indoor (H/M/L)
dB
41/35/31
39/33/26
Outdoor
dB
47
48
44
45
Refrigerant
Name of refrigerant
R22
Rated amount
kg
0.80
0.65
Refrigerant control
Capillary tube
Gas side size
mm
∅
12.70
∅
9.52
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
15*
1
10*
1
(One way)
Maximum height
m
6
5
difference
INDOOR UNIT
RAS-13UKPX2
RAS-10UKPX2
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
630
630
Air volume
Medium fan
m
3
/h
550
490
Low fan
m
3
/h
460
370
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-13UAX2
RAS-10UAX2
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight
kg
35
30
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
2030
2150
1740
1850
Fan motor output
W
30
20
Compressor
Model
PH160T2-4LH2
PH102T1-4CH
Output
W
1100
750
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°C
21 ~ 43