![Toshiba RAS-10UA-AS2 Service Manual Download Page 13](http://html.mh-extra.com/html/toshiba/ras-10ua-as2/ras-10ua-as2_service-manual_1135586013.webp)
– 12 –
FILE NO. SVM-03001
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13UKHP-ES2, RAS-13UKHP-AS2, RAS-10UKHP-ES2,
RAS-10UKHP-AS2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
MMF-240-20-4A-1
AC Motor with 135°C thermo fuse
2
Thermo sensor (TA-sensor)
———
10k
Ω
at 25°C
3
Switching transformer (T01)
SWT-47
4
Microcontroller unit (IC30)
TMP87CM40AN
5
Heat exchanger sensor
———
10k
Ω
at 25°C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7
Bridge rectifier (DB01)
D3SBA60
4A, 600V
8
Capacitor (C02)
KMH400VSSN47M22S
47
µ
F, 400V
9
Fuse (F01)
TSCR6.3A
T6.3A, 250VAC
10
Varistor (R21, R22)
15G561K
560V
11
Resistor (R01)
RF-2TK5R6
5.6
Ω
, 2W
12
Louver motor
MP24GA
12VDC
13
Relay (Comp., RY01)
DI12D1
Rating 20A/AC250V, 12VDC
14
Relay (Fan, RY03)
G5N-1A
Rating 3A/AC250V, 12VDC
15
Relay (Solenoide, RY04)
G5N-1A
Rating 3A/AC250V, 12VDC
4-2. Outdoor Unit (RAS-13UAH-ES2, RAS-13UAH-AS2, RAS-13UA-ES2, RAS-13UA-AS2)
No.
Parts name
Type
Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
1
Compressor
PA150X2T-4FM1
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
2.49
3.95
Output (Rated) 42W, 6poles, 1 phase, 220 – 240V, 50Hz
2
Fan motor (for outdoor)
HF-240-42B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
176.2
290.5
3
Running capacitor
DS45115CBPQC
AC 450V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371306CPN
AC 370V, 30
µ
F
(for compressor)
Solenoid coil
5
(for 4-way valve)
VHV-01AJ503C1
AC 220 – 240V, 50Hz
(for Heat pump model)