How to set WEEKLY TIMER

1.  Press 

 to enter WEEKLY TIMER setting.

 

2.  Press 

 to select desired day in sequence.

  The sequence of day symbol appears on the LCD.

 

    

SU 

 MO 

 TU 

 WE 

 TH 

 FR 

 SA

WEEKLY SUMO

TUWETHFRSA

(All day)

3.  Press 

 to select the program number.

• 

The program 1 is ready for setting while 

 is 

pressed PG-1 appears on the LCD.

• 

Press 

 to change the program number in 

the sequence program 1 to program 4.

 

PG-1

PG-  2

PG-    3

PG-      4

     

4.  Press 

  or 

 to select the desired time.

• 

The time can be set between 0:00 and 23:50 in 

 

10 minute intervals.

• 

Press and hold the button to change setting time 

for 1 hr.

• 

Only one of ON or OFF timer can be set on each 

program.

 

ON timer display

OFF timer display*

*OFF timer is used to stop the air conditioner only. 

The display does not show Operation mode, 

Temperature, Fan speed and others.

5.  Press 

 to select desired operation.

 

6.  Press 

 or 

 to select desired temperature.

• 

The temperature can be set between 17°C and 30°C.

7.  Press 

 to select the desired fan speed.

8.  Add operations, if required.

• 

Press 

 to use 8°C operation.  

(Notes: Fireplace cannot select and memorize in 

weekly function) 

• 

Press 

 to use ECO operation.

• 

Press 

 to use Hi-POWER operation.

• 

Press 

 to use Silent operation.

• 

Press 

FLOOR

 to use FLOOR operation. 

9.  Adding or editing the program.

 

The program can be set to perform on all the required 

days until 

 is pressed to confirm the setting 10. 

 

If adding or editing a program is required, please 

repeat steps 2 - 8 before setting confirmation.

10. After adding or editing, press 

 to confirm 

 

the setting*.

 

Operating Mode

Weekly timer running
Next program
Timer ON or OFF

Next operation 

time

Operating Temperature 

and Fan speed

Display after 

pressing SET 

button

Edit Weekly timer program

To edit the program after confirming the weekly timer 

setting, follow steps 1 - 3 below.

1.  Press 

.

• 

The day of the week and the program number of the 

current day will be displayed.

2.  Press 

 to select the day of the week and 

press 

 to select program number to be 

confirmed.

• 

Resetting the operation.

3.  Press 

 to exit confirming mode.

Deactivating WEEKLY TIMER operation

Press 

 while “WEEKLY” is displayed on the LCD.

• 

The “WEEKLY” indicator will disappear from the 

LCD. However, the program will remain in the remote 

control.

• 

The TIMER lamp goes off.

• 

To reactivate the WEEKLY TIMER operation, 

 

press 

 again, LCD shows the next program. 

The program after reactivation, is related to the clock 

time.

To delete programs

The individual program

1. Press 

.

• 

The day of the week and the program number is 

displayed.

• 

Select the day to delete the program.

2.  Press 

 to select the program number to be 

deleted.

3.  Press 

.

• 

ON or OFF timer will be cleared and the LCD will 

blink.

4.  Press 

 to delete the program.

• 

Press 

 while the LCD is blinking. 

 

The program has now been deleted.

All programs

1. Press 

.

• 

The day of the week and the program number will 

be displayed.

2. Press 

 and hold for 3 seconds.

• 

All programs will be deleted and LCD displays 

current operation.

Notes :

Make sure the remote control receiving module on the air 

conditioner receives the signal from the remote control.

WEEKLY TIMER OPERATION

23

Blink

*Point remote control at air conditioner receiving module 

then, press SET button until you hear the “BeepBeep” 

sound. This means the setting operation has been 

completed. As the air conditioner is receiving the signal, 

you will hear separate “Beep” sounds corresponding to 

the number of days in the selected setting. An incomplete 

setting is indicated if the TIMER lamp is blinking. Press 

 twice.

Notes :

1.  Place the remote control where the indoor unit can 

receive the signal. This will increase the accuracy 

of the timing between the remote control and the air 

conditioning unit.

2.  The ON/OFF timer can be set during the WEEKLY 

TIMER operation. In this situation, the air conditioner 

will first follow the normal timer until it is complete; 

then, it will return to the WEEKLY TIMER function.

3.  During WEEKLY TIMER operation, all of operation 

such as MODE, TEMP, FAN, Hi-POWER, ECO and 

etc., can be adjusted but when the clock reaches the 

program setting, the operation will return to the set 

items in the program.

4.  When the remote control is sending a signal to the air 

conditioner, avoid interference from objects that can 

block the signal.

IT
DE
PT
PL
CZ
GR

1112150124_EN.indd   7

2/28/2563 BE   11:27 AM

Summary of Contents for RAS-10U2FVG-NZ

Page 1: ...DE PT PL CZ GR AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 10 13 18U2FVG NZ Outdoor unit RAS 10 13 18U2AVSG NZ 1112150124 R32 OWNER S MANUAL 1112150124_EN indd 1 2 28 2563 BE 11 27 AM ...

Page 2: ...t operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children...

Page 3: ...se the appliance to heat flames sparks or other sources or ignition Else it may explode and cause injury or death CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium ...

Page 4: ...ssible to operate even when stopping To cancel CHILD LOCK function press MODE button for 3 seconds once again When CHILD LOCK function is activated 3 beeps will sound When press MODE button to cancel the function a beep will sound and then 3 seconds later 3 beep sound may occur The indicator button will be invalid while the child lock function is activated When press the button 1 beep will sound O...

Page 5: ...ote Keep the remote control in accessible transmission to the indoor unit otherwise the time lag of up to 15 minutes will occur The setting will be saved for the next same operation Press to cancel the daily timer operation Set your preferred operation for future use The setting will be memorized by the unit for future operation except airflow direction 1 Select your preferred operation 2 Press an...

Page 6: ...hborhood will have a tight sleep in nighttime By this feature the heating capacity will be optimized to deliver such silent experience The silent operation can be selected from one of two purposes Silent 1 and Silent 2 There are three setting parameters Standard level Silent 1 Silent 2 Silent 1 Though operating silently the Heating or Cooling capacity is still prioritized to ensure having sufficie...

Page 7: ...ing WEEKLY TIMER operation Press while WEEKLY is displayed on the LCD The WEEKLY indicator will disappear from the LCD However the program will remain in the remote control The TIMER lamp goes off To reactivate the WEEKLY TIMER operation press again LCD shows the next program The program after reactivation is related to the clock time To delete programs The individual program 1 Press The day of th...

Page 8: ...1112150124 1112150124_EN indd 8 2 28 2563 BE 11 27 AM ...

Reviews: