17
−
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
Reactor
L = 19mH, 10A
2
Outdoor fan motor
DC140V, 43W
3 Suction temp. sensor (TS sensor) 10k
Ω
(25°C)
4 Discharge temp. sensor (TD sensor) 62k
Ω
(20°C)
5 Outside air temp. sensor (TO sensor) 10k
Ω
(25°C)
6 Heat exchanger temp. sensor (TE sensor) 10k
Ω
(25°C)
7
Terminal block (5P) 20A, AC250V
9
COIL FOR P.M.V.
DC12V
10
Coil for 4-way valve
AC220-240V
CAM-MD12TCTH-2
STF-01AJ646A1
Compressor 3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ2
Parts name
Mode l na me
Rating
CH-69-Z-T
ICF-140-43-4R
No.
Fan motor (for indoor)
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3 Heat exchanger temp. sensor (TC-sensor) 10k
Ω
at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
MP24Z3T
AFN-220-20-4D AC240V, 20W
Part s n ame
1
Specif icat io ns
Type
JX0-5B
FILE NO. SVM-10029