<Inspection procedure>
1. Remove the front panel. (Remove 2 screws.)
2. Remove the cover of the fan motor lead wires.
3. Check AC voltage with CN31 connector while the fan motor is rotating.
NOTE :
• Using a tester, measure the resistance value of each winding coil.
• Use a thin test rod.
1
3
5
1
2
3
2
1
3
2
1
3
2
1
3
2
1
3
CN31
CN33
P.C. board
WHI
BLK
RED
BLK
RED
WHI
BLU
PUR
GRY
BLU
PUR
GRY
Resistance value
Position (P.C. board)
Between
3
(Black) -
1
(Red)
Between
3
(Black) -
5
(White)
BLK
WHI
RED
PUR
GRY
BLU
(4) Indoor fan motor automatically starts to rotate by turning on power supply
of "Judgment of Trouble by Every Symptom".
• Do not disconnect the connector while the fan motor is rotating.
• For P.C. board side, proceed to the item "Only indoor fan does not operate"
FILE NO. SVM-12057
–
77
–
RAS-10N3KVR-E,
RAS-13N3KVR-E
Between
1
(Red) -
5
(White)
373±26
Ω
249±17
Ω
622±44
Ω