88
Q9 ASD Installation and Operation Manual
RR Reference 2
Program
Frequency Settings
This parameter is used to set the gain and bias of the RR input terminal when the
RR terminal is used as the control input while operating in the Speed Control
mode or the Torque Control mode.
This parameter sets the RR input level that is associated with
when operating in the Speed control mode or is associated with the
when operating in the Torque Control mode.
This value is entered as 0% to 100% of the RR input signal range.
for more information on this setting when used for Speed
control.
See RR Torque Reference 1 (
) for more information on this setting when
used for Torque Control.
Direct Access Number — F212
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 100
Units — %
RR Frequency 2
Program
Frequency Settings
This parameter is used to set the gain and bias of the RR input terminal when the
RR terminal is used as the control input while operating in the Speed Control
mode.
and is the frequency that is associated with
when operating in the Speed Control mode.
See RR Reference 1 (
) for more information on this setting.
Direct Access Number — F213
Parameter Type — Numerical
Factory Default — 60.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (
Units — Hz