5.  Indications on display

Messages appearing on the display are classified into three, namely, title indications, malfunction

indications and alarm indications.

Title indications (function indications): Indicated by LED lamps

LED indication

Description

init

In initialization

chc

In checking of initial communication with inverter

copy

Copying function

comp

Comparing function

prot

Memory protecting function

clr

Memory initializing function

a

b

c

in

sys

sup

Name of objective
memory

a

 (memory A), 

b

(memory B), 

c

(memory C)

in

(inverter's memory), 

sys

(all memories), 

sup

(Special data)

_

 

_

-

_

 

_

Copying from 

_

 to

_

_

 

_

=

==

=

_

 

_

Comparing data of 

_

  with that of 

_

end

End of copying or comparing

0ff

0n

On/Off status of memory protection function or memory initializing function
(ON: to execute, OFF: not to execute)

f___

Communication number of parameter

00

 - 

ff

Result of check sum (hexadecimal number)

Malfunction indications: Indicated by blinking LED

LED indication

Description

raMe

RAM built in the parameter writer is abnormal.
If the same indication appears after resetting the parameter writer, it needs to repair.

roMe

ROM built in the parameter writer is abnormal.
If the same indication appears after resetting the parameter writer, it needs to repair.

eePe

E

2

PROM built in the parameter writer is abnormal.

If the same indication appears after writing (copying) data again, it needs to repair.

cpUe

CPU of the parameter writer is abnormal.
If the same indication appears after resetting the parameter writer, it needs to repair.

coMe

Abnormal communication

When communication is normally operated after the indication, the alarm mode (indication)

is automatically cancelled. If the same indication appears after checking connection of the
inverter's serial communication cable and resetting the parameter writer, the unit needs to repair.

Alarm indications (warning indications): Indicated by blinking LED

LED indication

Description

prot

The target memory to copy data or to initialize is write protected. You cannot copy data to the
memory or initialize that memory.

deVe

The type of device is different (different in type or capacity of inverter).

If you press the ENT key when you are copying between two inverters of different capacities, the

system executes a copying operation forcefully but the system ends the operation if you press the
ESC key. If you set “

sup

” (system area parameters) to “

off

” (protection disabled) with

prot

 (memory protection)” function, you cannot write data even if you press the ENT key.

If you have written data forcefully between two inverters with different capacities, we suggest you
execute a parameter initialization for each level of inverter capacity. See the inverter instruction
manual on how to initialize parameters.

erRa
erRb
erRc

When memory A (or B or C) is selected as the source of copying operation or when it is selected

with comparison and protection functions with no data in either case in the memory (including the
case when power was turned off during the previous copying operation), or when a check sum
error occurred, this indication appears.

Write data other than zero to the memory.

f___

Indicates the communication number of the parameter whose setting value is different.

clr

If you press the “STOP key” while an alarm message is displayed, “

clr

” flickers for one

second. If you press the “STOP key” again when “

clr

” flickers, the parameter writer will be

reset.

Summary of Contents for PWU001Z-1

Page 1: ... keypad 12 5 INDICATIONS ON DISPLAY 13 6 RESETTING FUNCTION 14 7 SPECIFICATIONS 14 8 WARRANTY 14 This Parameter Writer cannot use at TOSVERT VF S7 S7e inverter has a CPU whose version is V100 to V103 For checking the version number of the CPU refer to the Monitor paragraph in the instruction manual of the inverter Toshiba Corporation 1996 All Rights Reserved NOTES 1 Make sure that this instruction...

Page 2: ...mber of Parameter Writer PWU 001 Z 1 Revision number Cable length Connection cable between inverter and parameter writer Z Without Model number of parameter writer Symbol of parameter writer Check of accessories The Parameter Writer is shipped together with the following accessories in the same package On opening the packing case check to see if the following accessories are contained or not 1 Ope...

Page 3: ...fire Mandatory Wiring should be conducted after turning the inverter power off Turn off the power immediately in case any abnormalities such as smokes smells or abnormal noise are found Neglect of these conditions could lead to fire For repairs call your agency Transportation and installation Danger Prohibited Do not install or operate the inverter if it is damaged or any part is missing from it O...

Page 4: ...cuted securely from outside The integrity of data storage is guaranteed for up to 10 years The operating life of EEPROM data storage device is 10000 operations Do not execute writing operations more than 10000 times Do not turn off power or remove the connection cable between the inverter and the parameter writer while a copying operation of parameter writer is executed If the inverter power is tu...

Page 5: ...e parameter writer with data of the inverter 2 Comparing data of the inverter with data of the parameter 3 Comparing data of two memories of the parameter writer with each other 4 Memory protecting function Data written on the inverter s memory and the memories A B and C of the parameter writer are protected by this function to inhibit data writing 5 Memory initializing function A selected memory ...

Page 6: ...ESC key To be used to return to the status one before In remote keypad function DOWN key Memory C key Exclusive key for simply copying In the simply copying function this key is used to specify the memory C of the parameter writer as the origin to transmit data In remote keypad function MON key ENT key To be used to decide a function or memory or to execute the decided function In remote keypad fu...

Page 7: ...he parameter writer confirm that the PARAMETER WRITER lamp is on Or when this unit is used for the remote panel confirm the REMOTE PANEL lamp is on 5 If a change from the PARAMETER WRITER function to the REMOTE PANEL function mutually takes place turn off the power of the inverter and confirm that the LED display on the operation panel is turned off Then turn on the power of the parameter writer w...

Page 8: ... in a copying data from inverter memory to memory A to in b copying data from inverter memory to memory B in c copying data from inverter memory to memory C and to in a again in this order If the memory A is selected as the origin to copy data indications differently appear as shown in parentheses in a f000 f_ _ _ Entering the selected memory to transcribe copied data After selecting in a selectin...

Page 9: ... on the display changes to f_ _ _ of the communication number of the parameter being copied end _ _ two digits Copying is complete With completion of data copy end appears on the display first and then _ _ of a check data check sum of the origin of copied data appears Value of the check data changes depending on the condition of the original data _ _ copy Ending copying Press the ENT key and indic...

Page 10: ...rter memory for example with the SFT key press the ENT key and in a appears on the display in a in b in c in a a in a b a c a in Selecting a memory to compare its data with that of the previously selected memory Each time the SFT key is pressed indication on the display changes from in a comparing data between inverter memory and memory A to in b comparing data between inverter memory and memory B...

Page 11: ...ed setting mode selection f005 fmsl FM terminal meter selection f006 fm FM terminal meter adjustment f007 typ Standard setting mode selection f008 fr Forward reverse selection At panel control only f009 acc Acceleration time 1 f010 dec Deceleration time 1 f011 fh Maximum frequency f012 ul Upper limit frequency f013 ll Lower limit frequency f014 vl Base frequency 1 f015 pt Motor control mode select...

Page 12: ...a selecting memory A b selecting memory B c selecting memory C sup special parameter selection 1 and to in again in this order Select the memory to protect its data in off When the memory is protected the display changes to on from in Entering the memory to protect its data After selecting in selecting inverter memory by way of example with the SFT key press the ENT key and the display shows the p...

Page 13: ...y and 0ff not to initialize the selected memory 0n init c0py Executing initialization of the selected memory After selecting on selecting inverter s memory for example with the SFT key press the ENT key and the parameter writer starts initializing the selected memory with indication of init appearing on the display When initialization of the selected memory is complete indication of the display re...

Page 14: ...cation the alarm mode indication is automatically cancelled If the same indication appears after checking connection of the inverter s serial communication cable and resetting the parameter writer the unit needs to repair Alarm indications warning indications Indicated by blinking LED LED indication Description prot The target memory to copy data or to initialize is write protected You cannot copy...

Page 15: ...llation and operation within one year after delivery and the trouble clearly originated in the design or manufacture of the unit the manufacturer is responsible for the trouble and the unit will be repaired by it free of charge 2 The warranty applies to the delivered Parameter Writer only 3 The user will be charged for the following repair service though the term of the warranty is not expired 1 T...

Page 16: ......

Reviews: