P9 ASD Installation and Operation Manual
127
Jog Run Frequency
Program
Frequency
Jog Settings
This parameter sets the output frequency of the ASD during a
Jog
.
Jogging
is
the term used to describe turning on the motor for small increments of time and
is used when precise positioning of motor-driven equipment is required.
The
Jog
function is initiated via the
Terminal Board
or
using
Communications
(see the
7-Series Serial
Communications User Manual
(P/N 53840) for additional information on using
Communications
for
Jogging
).
To perform a
Jog
, set this parameter (
) to the desired
Jog
frequency.
Select a
Jog Stop
method (
).
Jog Run Using the Terminal Board
To initiate a
Jog
from the
Terminal Board
,
perform the following:
1.
Assign an unused discrete input terminal to the
Jog
setting.
2.
Assign a discrete input terminal to the
F
(Forward) function (and Reverse if
3.
Provide a
Forward
(and/or
Reverse
) command from the
Terminal Board
.
4.
Place the system in the
Auto
mode (Hand/Auto LED is off).
5.
Activate the
Jog
terminal of
.
The system will run at the
speed for the duration of the terminal activation
method upon terminal deactivation.
Direct Access Number — F260
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 20.0
Units — Hz
Jog Stop Pattern
Program
Frequency
Jog Settings
This parameter sets the stopping method used while operating in the
Jog
mode.
Note:
This parameter setting is used for the
Jog
operation only. The
Emergency Off
stopping method setting of
has priority
over this setting, and changes made here do not affect the
function or setting of
Settings:
0 — Deceleration Stop
1 — Coast Stop
2 — DC Injection Braking Stop
Direct Access Number — F261
Parameter Type —
Selection List
Factory Default —
Deceleration Stop
Changeable During Run —
Yes