PREPARATION FOR SERVICING
How to use the Servicing Fixture
1.
2.
3.
4.
5.
6.
Unplug the connector CP351, CP355, CP502 and CP353, then remove the TV/VCR Block from the set.
Unplug the connector CP810, CP820 and CP850, then remove the Main PCB from the VCR Block.
Connect as shown in the below figure using the Service Fixture.
• Connect the Syscon PCB to the Main PCB with the cable JG162C and JG162D.
• Connect the Syscon PCB to the CRT PCB with the cable JG162Y.
Remove the Jack/LED PCB from the set, then connect it with the Syscon PCB.
If necessary, connect CP351 (Front A/V Jack Input Terminal)
Short circuit between TP1001 and Ground with the cable JG154.
(Refer to MAJOR COMPONENTS LOCATION GUIDE)
The EOT, BOT and Reel Sensor do not work at this moment.
At that time, the STOP/EJECT button is available to insert and eject the Cassette Tape.
CP820
Main PCB
JG154
To Ground
JG162Y
TP1001
Front Cabinet
CRT PCB
CP850
CP804
CD850
CD820
CD810
CD352
Jack/LED PCB
CD351
Syscon PCB
CP810
JG162C
JG162D
CD601
CP355