ELECTRICAL ADJUSTMENTS
D3-4
2-19: COLOR LEVEL
1.
2.
3.
Receive the color bar pattern. (RF Input)
Connect the oscilloscope to pin 6 of CP602.
When setting to the Y-LEVEL 100%, check if the
MAGENTA is 45
±
10%. (Refer to Fig. 2-5)
Fig. 2-5
100%
45%
Magenta
2-20: E-E LEVEL
1.
2.
3.
Receive the color bar pattern. (Audio Video Input)
Connect the oscilloscope to pin 6 of CP602.
Check if the VIDEO OUTPUT LEVEL is 1
±
0.2Vp-p.
(Refer to Fig. 2-6)
Fig. 2-6
1.0Vp-p