background image

6

 Louver 

direction

NOTE

To improve the cooling / heating performance, change 
the louver angle for each operation.

The characteristics of air: Cool air falls, and warm 
air rises.

 

CAUTION

Point the louver horizontally during cooling

If pointing downward for cooling, dew may form on the 
surface of the air discharge or louver and may drop 
down.

NOTE

•  If pointing horizontally for cooling, dew may form on 

the surface of the cabinet or louver and may drop 
down.

•  If pointing horizontally for heating, the room 

temperature may be uneven.

•  Do not handle the louver manually.
•  Doing so may cause a failure.
•  Use the remote controller to adjust the angle.

‹

  To set the louver direction and 

auto swing

1

Push the Menu button several times and select 
the wind direction mode to blink the wind direction.
Then, push the setting button several times to 
display the louver direction as shown in the 

fi

gure 

below.
•  If you do not push any button for 30s, the wind 

direction mode 

fi

nishes.

T

 For heating

The louver can be adjusted to six steps.
Point the louver downward. If not pointing 
downward, hot air may not reach the 

fl

oor.

Initial

(1)

(2)

(3)

(4)

(5)

(6)

Swing

Operation mode

Available directions

HEAT, FAN

(1)   (2)   (3)   (4)   (5)   (6)

T

 For cooling

The louver can be adjusted to four steps.
Point the louver horizontally. If pointing downward, 
dew may form on the surface of the air discharge 
port and may drop down.

Initial

(1)

(2)

(3)

(4)

Swing

Operation mode

Available directions

COOL, DRY,

(1)   (2)   (3)   (4)

T

 For fan

The louver can be adjusted to six steps.
Select a wind direction.

 

 Auto swing

The SWING   indicator is displayed and the 
louver begins swinging.

Repeat

 

 4-way cassette type

T

 When cooling

Point the louver horizontally.

T

 When heating

Point the louver downward.

•  The louver automatically closes when running is 

stopped.

•  In pre-heating mode, the louver points upward.

The swing indication appears on the remote 
controller even in pre-heating mode, but the actual 
swing starts only after pre-heating is complete.

 

 2-way cassette type

T

 When cooling

Point the louver horizontally to send cool air across the 
entire room.

T

 When heating

Point the louver downward to send heated air to the 

fl

oor.

 

 1-way cassette type 

(SH series)

T

 When cooling

Point the louver horizontally to send cool air across the 
entire room.

T

 When heating

Point the louver downward to send heated air to the 

fl

oor.

•  The louver automatically closes when running is 

stopped.

•  In pre-heating mode, the louver points upward.

The swing indication appears on the remote 
controller even in pre-heating mode, but the actual 
swing starts only after pre-heating is complete.

– 11 –

21-EN 

22-EN

Summary of Contents for MMY-MUP0801HT8JP-E

Page 1: ...E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8JP E MMY MUP1801HT8JP E MMY MUP2001HT8JP E MMY MUP2201HT8JP E MMY MUP2401HT8JP E English ...

Page 2: ...tters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating...

Page 3: ...ould result in slight injury 2 or damage 3 to property if the product is handled improperly 1 Serious bodily harm indicates loss of eyesight injury burns electric shock bone fracture poisoning and other injuries which leave aftereffect and require hospitalization or long term treatment as an outpatient 2 Slight injury indicates injury burns electric shock and other injuries which do not require ho...

Page 4: ...is work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you instal...

Page 5: ...nt Be sure to stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of error such as when an error display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in th...

Page 6: ...m the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave f...

Page 7: ... HP For details on these models read the owner s manuals that come with the indoor units Console MML UP NHP For details on these models read the owner s manuals that come with the indoor units Hot Water Module MMW UP LQ For details on these models read the owner s manuals that come with the indoor units 2 Part names Outdoor unit Air discharge Warm air comes out when cooling and cool air when heati...

Page 8: ...ype MMU UP YHP Air intake grille Air in the room is taken in through here Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille MMU UP SH Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air intake grille Air in the room is taken in through h...

Page 9: ... H Discharge louver Controls discharge air directions Earth screw Air intake grille Air in the room is taken in through here Air filter Filters out dust Inside the return air grille Floor Standing Concealed Type MML UP BH Drain funnel with strainer Accessory to be attached at the site Air filter Filters out dust Inside the return air grille Front panel lower Air discharge Earth screw Equipped on t...

Page 10: ...ral control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that the model is being checked automatically after a breaker is throw...

Page 11: ...cted Auto cannot be selected at the Fan mode FIX is displayed for models capable of the fan speed setting If you do not push any button for 30s the fan speed mode finishes If you do not push any button for 30s the operation mode finishes 4 Select the temperature Push the setting button to adjust the temperature The temperature setting range is 18 0 C to 29 0 C The temperature can be set in steps o...

Page 12: ...ooling The louver can be adjusted to four steps Point the louver horizontally If pointing downward dew may form on the surface of the air discharge port and may drop down Initial 1 2 3 4 Swing Operation mode Available directions COOL DRY 1 2 3 4 T For fan The louver can be adjusted to six steps Select a wind direction Auto swing The SWING indicator is displayed and the louver begins swinging Repea...

Page 13: ...rd in COOL mode water droplets may form on the surface of the cabinet or louver and drop down When the horizontal louver is pointing horizontally in HEAT mode the air may not warm up the room evenly Floor standing type Vertical adjustment T When cooling Move the louver manually and point it horizontally to send cool air across the entire room T When heating Move the louver manually and point it do...

Page 14: ...areas near oceans etc Hot springs emitting sulfidizing gas etc Heavily acidic or alkaline places e g place disinfection solution is frequently sprayed at Special maintenance or parts are required for use in the above places For details contact the dealer where you purchased the product Leave an enough space around the air intake and discharge of the outdoor unit so that the ventilation is not rest...

Page 15: ... intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air discharge of the outdoor unit During heating When dust or dirt is excessively adhered to the air filter of the indoor unit When the air discharge of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Coolin...

Page 16: ... Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 25 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp If air conditioner is used outside of the above co...

Page 17: ...deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended...

Page 18: ...y Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to Low Med and is the operation mode set to Fan Is the setup temp the appropriate temperature Are Cool and Heat selected simultaneously indication is lit on the display of the remo...

Page 19: ...EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMY MUP0801HT8P E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8...

Page 20: ...1141002201 ...