Concealed Duct Standard Type

Concealed Duct High Static Pressure Type

MMD-AP018

H

 to AP048

H

MMD-AP072

H

 to AP096

H

Slim Duct Type

Air filter

Filters out dust.

(Inside the return air grille)

Air discharge

The air discharge duct is connected.

Earth screw

Equipped on the electrical control 
box.

Return air grille

Air in the room is taken in through 
here.

Earth screw

Equipped on the electrical control

box.

Air discharge

The air discharge duct is connected.

Return air grille

The return air duct is connected.

Drain pan

Electrical control box

The earth screw is provided in the
electrical control box.

Air discharge

Connect a discharge duct.

Air intake

Connect a suction duct.

Drain pan

Air filter

Filters out dust.

(Inside the return air grille)

Return air grille

The return air duct is

connected.

Earth screw

Equipped on the electrical control 
box.

Air discharge

The air discharge duct is 
connected.

Ceiling Type

Floor Standing Cabinet Type

Floor Standing Concealed Type

Floor Standing Type

Air filter

Filters out dust.

(Inside the return air grille)

Discharge louver

Controls discharge air

directions.

Return air grille

Air in the room is taken in through 
here.

Earth screw

Equipped on the electrical control 
box.

Air filter

Filters out dust.

(Inside the return air grille)

Discharge louver

Controls discharge air directions.

Earth screw

Return air grille

Air in the room is taken in through 
here.

Air discharge

Drain funnel (with strainer)

Accessory to be attached at the site

Air filter

Filters out dust.
(Inside the return air grille)

Front panel (lower)

Earth screw

Equipped on the electrical

control box.

Air intake

Air in the room is taken in

through here.

Discharge louver

Controls discharge air directions.

Metal fittings

Vertical louver

Automatically directs the airflow 
horizontally at regular intervals.

Drain pan

Water collected here is drained out 
through the drain pipe.

Metal fittings (left / right)

Earth screw

Equipped on the electrical

control box.

Air filter

Filters out dust

Air intake

Air in the room is taken in

through here.

11-EN

12-EN

Summary of Contents for MMY-MAP0501HT8-E

Page 1: ...MMY MAP0801HT8ZG E MMY MAP1001HT8 E MMY MAP1001HT8Z E MMY MAP1001HT8ZG E MMY MAP1201HT8 E MMY MAP1201HT8Z E MMY MAP1201HT8ZG E Cooling Only Model MMY MAP0501T8 E MMY MAP0501T8Z E MMY MAP0501T8ZG E MMY MAP0601T8 E MMY MAP0601T8Z E MMY MAP0601T8ZG E MMY MAP0801T8 E MMY MAP0801T8Z E MMY MAP0801T8ZG E MMY MAP1001T8 E MMY MAP1001T8Z E MMY MAP1001T8ZG E MMY MAP1201T8 E MMY MAP1201T8Z E MMY MAP1201T8ZG E...

Page 2: ...knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work o...

Page 3: ...breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you install the unit in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the dealer from whom you purchased the air conditioner when you implement the measures Accum...

Page 4: ... Installation fuse all types can be used must be used for the power supply line of this air conditioner Installation Certainly lay the drain hose for perfect draining Bad drainage may cause flooding in the house and getting furniture wet Make sure to connect the air conditioner to an exclusive power supply of the rated voltage otherwise the unit may break down or cause a fire Confirm that the outd...

Page 5: ... H E Fresh Air Intake MMD AP HFE For details on these models read the owner s manuals that come with the indoor units Air to Air Heat Exchanger with DX Coil Unit MMD VNK HEXE MMD VN HEXE For details on these models read the owner s manuals that come with the indoor units High wall compact MMK AP MH E For details on these models read the owner s manuals that come with the indoor units High wall MMK...

Page 6: ...e room is taken in through here Discharge louver Controls discharge air directions 2 way Cassette Type 1 way Cassette Type MMU AP007 YH to AP012 YH MMU AP015 SH to AP024 SH Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Air filte...

Page 7: ...anding Cabinet Type Floor Standing Concealed Type Floor Standing Type Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Eart...

Page 8: ...r sensor indicator Displayed when the remote controller sensor is used 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 No function indicator Displayed when the function requested is not available on that model 14 Fan speed indicator Indicates the selected fan speed 15 ...

Page 9: ...d and floor standing cabinet fresh air intake types 8 Operation lamp Lights up during running Blinks when an error occurs or the protective device activates 9 button Turns on the unit when pushed and turns off when pushed again 10 button Operation mode select button Selects desired operation mode 1 8 3 5 2 9 10 6 7 12 4 11 SWING FIX 11 button Unit Louver select button Selects a unit number left an...

Page 10: ...The fan speed selection function is not available for the concealed duct high static type Fan speed is fixed and the indicator is fixed to High SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 2 Heat pump model Heat Dry Cool Fan Dehumidify Cooling only model Dry Cool Fan Dehumidify Low Medium High Auto Changing the set temperature 1 Push the TEMP butto...

Page 11: ...ing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the air conditioner in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations ...

Page 12: ...ioner If the protective device activates the unit s running stops and the operation lamp blinks When the protective device activates the indicator and the check code are displayed on the remote controller The protective device may activate in the following cases During cooling When the air intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air di...

Page 13: ...COOL DRY operation the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Unit select When two or more indoor units are controlled with one remote controller the louver direction can be set for each indoor unit by selecting them individually To set louver direction in...

Page 14: ...display Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 Swing code Swing Horizontal Downward Downward Horizontal Downward Downward Horizontal Horizontal Cyclic swing Recommended for cooling All four louvers swing at different times like waves Setting the louver lock 1 Push and hold the button right side of the button for at least 4 seconds while running is stopped blinks When no unit number is dis...

Page 15: ...ction setting 0000 Smudging reduction position reduces ceiling smudging factory default 0002 Cold draft position Less directly expose your body to cool air 0000 SET DATA UNIT LOUVER Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 No display 4 way cassette type The louver automatically closes when running is stopped In pre heating mode the louver points upward The swing indication appears on the re...

Page 16: ... GOOD GOOD Ceiling type Vertical adjustment The louver automatically points upward when running is stopped In pre heating mode the louver points upward The swing indication appears on the remote controller even in pre heating mode but the actual swing starts only after pre heating is complete Horizontal adjustment 1 way cassette YH series and floor standing types Setting the direction and swinging...

Page 17: ... louvers slightly and point them in your preferred directions 1 2 In this case do not use the auto swing function Floor standing cabinet type Changing the air discharge Follow the procedure below to change the air discharge 1 Remove the two fixing screws of the air discharge The fixing screws are to be reused 2 Insert your hand into the air discharge and pull it up slightly then remove the air dis...

Page 18: ...et bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 20 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp Check periodically Do not cool down too much Close 10Maintenance WARNING For daily maintenance including Air Filter cleanin...

Page 19: ...hapter Wipe with a dry soft cloth If heavily stained wipe off dirt with a cloth soaked in lukewarm water Do not use water to wipe the remote controller Do not use benzine thinner scouring powder chemical cloth etc as those may cause deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then...

Page 20: ... not cooled or warmed sufficiently Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to LOW MED and is the operation mode set to FAN Is the setup temp the appropriate temperature Are COOL and HEAT selected simultaneously indication ...

Page 21: ...APAN Authorized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Heat Pump Model MMY MAP0501HT8 E MMY MAP0501HT8Z E MMY MAP0501HT8ZG E MMY MAP0601HT8 E MMY MAP0601HT8Z E MMY MAP0...

Page 22: ... 21 MEMO ...

Page 23: ... 22 MEMO ...

Page 24: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: