28
1P SR (1 Pulse Trigger Sync Reset)
( 2 )
#HARGEBEGINSTOACCUMULATEAFTERTHETRIGGERINPUTTO##OFTHE$)')4!,TERMINALTHEVERTICALSYNCSIGNALISRESET
and frame images are output.
1 Pulse Trigger SYNC-RESET Picture Output Timing
(2. 1)
About 1
m
s
Exposure completion
0 to 1H*
3
Exposure period*
2
Trigger*
1
Negative polarity mode
Positive polarity mode
(Internal VD)
FVAL
RGB data
(video interval image)
LVAL,
DVAL
20H (Partial scanning/binning OFF)
10H (Partial scanning 93fps)
12H (Partial scanning 121fps)
12H (Partial scanning 126fps)
14H (Partial scanning 174fps)
14H (Partial scanning 199fps)
15H (Partial scanning 250fps)
14H (binning)
*
4
*1: External input signal
*2: Exposure time is determined by the setting of “7. 2 (1.3) Changing each setting in E.TRG mode”.
6$ISGENERATEDAFTERTO(FOLLOWINGTHECOMPLETIONOFTHEEXPOSUREPERIODANDTHEVIDEOISSYNCHRONIZEDTO
this and output.
*4: When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there
will be an effect on the video.