Data
Item
Address
H
L
Action
00H
AUTO
01H
MANUAL
MODE
20H
**H
02H
OFF
Sets the master gain mode.
AUTO MAX
21H
**H
00H
↓
12H
00dB
↓
18dB
Sets the maximum gain when the master gain is AUTO mode.
GAIN
MANU
22H
**H
00H
↓
12H
00dB
↓
18dB
Sets the gain when the master gain is manual.
00H
AWB
01H
ATW
MODE
30H
**H
02H
MANUAL
Sets the white balance mode.
00H
3200K
C.TEMP
31H
**H
01H
5600K
Sets a color temperature.
R PAINT
32H
**H
F6H
↓
00H
↓
0AH
-10
↓
00
↓
10
Sets the RED setting in AWB mode.
B PAINT
33H
**H
F6H
↓
00H
↓
0AH
-10
↓
00
↓
10
Sets the BLUE setting in AWB mode.
00H
PRESET A
01H
PRESET B
02H
PRESET C
03H
PRESET D
WHITE
BALANCE
AREA
34H
**H
04H
PRESET E
Sets in AWB mode.
PRESET A,B,C,D,E : in the specified range