11
㽲
Refer to the item “5. CONNECTION”, connect the equipment correctly.
A camera head "IK-CT1H" needs to be connected to this camera control unit from this section on.
㽳
Turn on the connected equipment and the camera.
㽴
When using the camera for the first time and when replacing the camera cable and the camera head, be
sure to perform the ABB adjustment, refer to the item “6.1 Initializing”.
㽵
㽶
Refer to the item “6.2 White Balance”, make the adjustment.
Refer to the items “6.3 Scene File, 6.4 Gain, 7. MODE SETTING BY THE ON SCREEN DISPLAY”,
select the necessary items.
Initilizing is necessary when the camera head is changed or used for the first time after purchase.
䊶
Close the lens iris not to stream. Streaming makes adjustment difficult.
䊶
If the color bar pattern is displayed on the screen or if the index menu/menu is displayed, press the [DISP]
button to disable the color bar pattern or the character display.
䊶
Hold the [DATA DOWN] button for approx. 1 second.
䊶
When initializing starts, the character INITIALIZE blinks on the screen.
䊶
When initializing finishes, the character INITIALIZE stops blinking and the result appears for
approx. 1 second.
Meaning
Display
INITIALIZE OK
Initializing finished correctly.
INITIALIZE NG
CLOSE LENS
Initializing cannot be performed because the lens iris is open.
Close the lens iris.
INITIALIZE NG
Initializing cannot be performed.
Try initializing again.
6
OPERATION
6
1 Initializing
IK-CT1C̲EN.indd 11
IK-CT1C̲EN.indd 11
2008/02/14 12:12:44
2008/02/14 12:12:44