background image

- 3 -

• The CAUTION label, shown on the left,

is attached on the camera.

CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightening flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the product’s enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock to
persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

WARNING :
TO  REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR
MOISTURE.

CAUTION :
CONNECT 24V AC UL LISTED CLASS 2
POWER SUPPLY.

FIELD INSTALLATION MARKING :
THIS INSTALLATION SHOULD BE
MADE BY A QUALIFIED SERVICE
PERSON AND SHOULD CONFORM TO
ALL LOCAL CODES.

FCC (USA)-INFORMATION
NOTE :
 This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.

USER-INSTALLER CAUTION : Your authority to operate this FCC verified equipment could
be voided if you make changes or modifications not expressly approved by the party.

01_p2-p32

06.8.7, 11:08 AM

3

Summary of Contents for IK-6200A

Page 1: ... 10 8 AUTOMATIC ELECTRONIC SHUTTER AES 11 9 BACKLIGHT COMPENSATION BLC 11 10 NOTES ON USE AND INSTALLATION 12 11 IN CASE OF PROBLEMS 12 12 SPECIFICATIONS 13 13 EXTERIOR VIEW 15 Please read this manual thoroughly before use and keep it handy for future reference Record in space provided below the Model and the Serial as found on the label on the bottom of this unit Model Serial Retain this informat...

Page 2: ...uct during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the power supply and cable system This will prevent damage to the video product due to lightning and power line surges If lightning occurs do not touch the unit or any connected cables in order to avoid electric shock 14 Overloading Do not overload the power ...

Page 3: ...ISTED CLASS 2 POWER SUPPLY FIELD INSTALLATION MARKING THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORMTO ALL LOCAL CODES FCC USA INFORMATION NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference ...

Page 4: ...e subject brightness 5 Back Light Compensation BLC adjusts for strong backlight conditions 6 White balance is automatically adjusted depending on color temperature variations AWB 7 Easy back focus adjustment for an easy installation 8 Built in 1 3 inch high resolution CCD IK 6410A 9 Minimum illumination of 0 2 lux at F1 2 IK 6210A Minimum illumination of 0 2 lux at F1 0 IK 6410A 10 S N ratio of 50...

Page 5: ...to a TV monitor etc AES VIDEO DC select switch AES Auto electronic shutter function VIDEO When using Al lens with amp DC When using AI lens without amp LEVEL DC Type AI Lens adjustment trimmer Select switch Line Lock mode ON OFF BLC ON OFF V PHASE Line Lock Phase adjustment terminal Auto IRIS Terminal Focus ring Rotate the ring to appropriate setting Focus Lock Screw Dimensions mm inch 01_p2 p32 0...

Page 6: ...LLATION Installation Example 1 4 20UNC 112 4 41 15 0 59 The Installation example is for reference only Mounting bracket is not included Dimensions mm inch Wall 9 5 0 37 4 0 16 φ6 0 24 80 3 15 01_p2 p32 06 8 7 11 08 AM 6 ...

Page 7: ...ctors and coaxial cable are not supplied with the camera Notes on connecting 5 1 Basic connection Single system configuration The recommended power supplies for this camera are 6 watt minimum for each 24V AC UL Listed Class 2 power supply or 12V DC power supply Do not overload power supply CAUTION Never input 24V AC and 12V DC at the same time Recommend power cord is twisted pair line with a minim...

Page 8: ... Hz covering a normal fluctuation of the power frequency However the camera may not cover a large fluctuation caused from the power generated by an engine generator etc It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on This is normal because several seconds are required to stabilize the camera against power noise Refer to 7 LINE LOCK PHASE fo...

Page 9: ... Auto iris Lens This camera supports two types of auto iris lens Video and DC direct drive types Connect the auto iris connector plug to the IRIS terminal on the side of the camera Refer to the chart below for correct wiring and Video IRIS Direct Drive Lens IRIS Lens 1 12V Damp y 2 NC Damp γ 3 VIDEO Driver wh 4 GND Driver g IRIS Switch VIDEO position DC position IRIS terminal pin Focus Lock Screw ...

Page 10: ... the video switcher the picture on the monitor TV will fluctuate vertically Connect 24V AC input lines of all cameras so that they all share the same phase If you still have vertical fluctuation adjust the V PHASE controller V PHASE CONTROLLER Note Refer to 5 2 Line Lock Control 01_p2 p32 06 8 7 11 08 AM 10 ...

Page 11: ...BLC To activate backlight compensation set the BLC switch to ON BLC ON OFF When the automatic electronic iris feature is used with an auto iris lens the exposure adjustment is automatically performed so that a best picture is obtained at a monitor zone of about 50 in horizontal and about 50 in vertical direction This function is effective when a strong light enters the portion other than this zone...

Page 12: ...r a TV set noise may appear in images In this event relocate cables or reinstall equipment Check the ambient temperature and humidity Avoid using the camera where the temperature is hotter or colder than the specified operating range Doing so could affect the internal parts or cause the image quality to deteriorate Special care is required to use the camera at high temperature and humidity Should ...

Page 13: ...mum illuminance of subject 0 2 lux F1 2 More than 10 of image output γ 0 45 S N 50 dB or more weight ON Video output VBS 1 0 V p p 75 ohms composite Output impedance 75 ohms unbalanced White balance Automatic 2500 K to 10 000 K Iris control Video Out Iris Driver Circuit Built in Gain control Average AGC 26 dB Backlight compensation Manual ON OFF switching center zone light measuring system Lens mo...

Page 14: ...inance of subject 0 2 lux F1 0 More than 10 of image output γ 0 45 S N 50 dB or more weight ON Video output VBS 1 0 V p p 75 ohms composite Output impedance 75 ohms unbalanced White balance Automatic 2500 K to 10 000 K Iris control Video Out Iris Driver Circuit Built in Gain control Average AGC 26 dB Backlight compensation Manual ON OFF switching center zone light measuring system Lens mount CS mo...

Page 15: ... 15 13 EXTERIOR VIEW 1 4 20UNC 1 4 20UNC 63 2 48 3 5 Dimensions mm inch 116 4 57 50 1 97 01_p2 p32 06 8 7 11 08 AM 15 ...

Page 16: ...HE IMPLIEDWARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU IF THIS PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED ABOVE YOUR SOLE AND EXCLUSIVE REMEDY SHALL BETHE REPAIR OF REPLACEMENT OFTHE PRODUC...

Reviews: