– 26 –
Hydro Unit
Installation Manual
■
Information input
• Register information about the contact number for
Service, model name and serial number of the Hydro
Unit and Outdoor Unit.
(1) Press the [
] / [
] button to select
“Information input” on the “FIELD SETTING MENU”
screen, then press the [
] button.
Service contact tel No.
(1) Press the [
] / [
] button to select
“Service contact tel No.” on the Information input
screen, then press the [
] button.
(2) Press the [
] / [
] button or [
] / [
]
to select the value, then press the [
] button.
Outdoor (Hydro) model name
Outdoor (Hydro) Unit serial No.
(1) Press the [
] / [
] button to select
“Outdoor model name (Hydro model name, Outdoor
serial No., Hydro serial No.)” on the Information
input screen, then press the [
] button.
(2) Press the [
] / [
] button to select
registration menu.
When you enter the model name (serial No.) by
yourself, select “Manual model name input”
(“Manual serial No. input”)
Press the [
] / [
] button or [
] / [
]
to select the character (the selected character is
highlighted), then press the [
] button. The
character is displayed on the upper part of the
screen from left-hand side.
If the [
] button is pressed in the state where
“Del” is selected, contents currently displayed is
deleted from right-hand side.
Press the [
] button in the state where “Fix” is
selected to register contents currently displayed on
the upper part of the screen.
Test mode
FIELD SETTING MENU(1/2)
Floor drying
Forced defrosting
Information input
Alarm history
SET
Service contact tel No.
Information input
Outdoor model name
Outdoor serial No.
Hydro model name
SET
Hydro serial No.
Service contact tel No.
FIX
Input telephone number
Service contact tel No.
Information input
Outdoor model name
Outdoor serial No.
Hydro model name
Hydro serial No.
SET
Manual model name input
Outdoor model name
Outdoor model name
SET
HWT-1101HW-E
Model name selection
HWT-1101HW-E
SET
Del
Fix
Select “Model name selection”, then press [
]
button. And, select “Remote controller”, then press
[
] button.
When you select “Outdoor Unit” (“Hydro Unit”) in
model name selection screen, factory default value
will be displayed in information screen.
•After Information input has been finished, confirm
the item “Information” on the “MENU” screen to
check the information is registered correctly.
■
Alarm history
• List of latest 10 alarm data: error information of error
code, date and time is displayed.
(1) Press the [
] / [
] button to select “Alarm
history” on the “FIELD SETTING MENU” screen,
then press the [
] button.
To reset the alarm history
(1) Press the [
] button to reset the alarm history.
(2) Press the [
] button, then all alarm data is
cleared.
Manual model name input
Outdoor model name
Outdoor model name
SET
HWT-1101HW-E
Model name selection
Remote controller
Model name selection
SET
Outdoor Unit
FIX
Test mode
FIELD SETTING MENU(1/2)
Floor drying
Forced defrosting
Information input
Alarm history
SET
Alarm history(1/3)
RESET
Code
Date
Time
Alarm history
NO
YES
Reset all alarm data?
51-EN
52-EN
Summary of Contents for HWT-1101F21MM3W-E
Page 39: ...0714305099 1 ...