– 18 –
Hydro Unit
Owner’s Manual
Setting – Schedule setting –
• This function is available only for the header remote
controller.
(1) Press the [
] / [
] button to select
“Setting” on the MENU screen, then press the [
]
button.
(2) Press the [
] / [
] button to select
“Schedule setting” on the setting screen, then press
the [
] button.
Condition setting
• Up to 6 different running patterns per day can be
programmed.
(1) Press the [
] / [
] button to select
“Condition setting” on the Schedule setting screen,
then press the [
] button.
(2) Press the [
] button to select the day, then press
the [
] button to input running pattern.
(3) Press [
] / [
] button to select the change item,
then press the [
] / [
] button.
(4) Press the [
] button.
(5) Press the [
] button to Fix.
Mode : Operation mode (HEAT, COOL, HW (Hot
water))
Z1
: ZONE1 setting temperature
Z2
: ZONE2 setting temperature
HW
: Hot water supply operation setting
temperature
Start : Operation start time (0:00 ~ 23:59)
End
: Operation end time (0:00 ~ 24:00, -- : --)
• “-- : --” means the operation continues.
If End time is set earlier than Start time, an error is
displayed.
Anti bacteria
MENU(2/2)
Frost protection
Setting
Information
SET
Initial setting
Setting
Schedule setting
SET
Condition setting
Schedule setting
Holiday setting
SET
Key lock
-- -- -- -- -- : -- -- : --
-- -- -- -- -- : -- -- : --
-- -- -- -- -- : -- -- : --
Condition setting(1/2)
ALL
MON
TUE WED THU FRI SAT SUN
Mode
Start
End
SET
DAY
COPY
RESET
Z1
Z2
HW
55 45 -
- 08:00 22:00
25 - -
- -
23:00 - - : - -
- -
- -
65 18:00
19:00
Condition setting(1/2)
ALL
TUE WED THU FRI SAT SUN
Mode
Start
End
FIX
RESET
Z2
HW
Z1
COOL
HW
MON
HEAT
Schedule timer confirm?
Condition setting
NO
YES
18-EN