background image

 

Installation Notes

  

ƒ

 

The drive should be mounted carefully on the surface of 0.1mm or less flatness to avoid 
excessive distortion.  

ƒ

 

In order to prevent short-circuit under any circumstances, a space of 0.5mm or more should be 
kept under the PCB.  

ƒ

 

Space should be kept around the drive to avoid any contact with other parts, which may occur 
due to shock or vibration.  

ƒ

 

The temperature of the top cover and the base must always be kept under 60C to maintain the 
required reliability.  

ƒ

 

Be sure not to cover the breathing hole to keep the pressure inside the drive at a certain level  

ƒ

 

Do not apply any force to the top cover, except the screw areas on top cover. Maximum force to 
the specified area is 2N.  

ƒ

 

The drive contains several parts which may be easily damaged by ESD (Electric Static 
Discharge). Avoid touching the interface connector pins and the surface of PCB. Be sure to use 
ESD proof wrist strap when handling drive.  

ƒ

 

The four mounting screws should be tightened equally with 0.3N-m (3kgf-cm) torque. The depth 
should be 3.0mm minimum and 3.5mm maximum.  

Placing Hard Drive inside your Computer

   

 

Determine mounting configuration (the drive can be mounted in either a horizontal or vertical 
orientation)  

 

Configure drive for system application.  

 

Configure the adapter board for the specific system application (if required).  

 

Install adapter board into an unused PC/AT 16 bit slot (if required).  

 

Install the I/F cable to the system's 44 pin connector port or adapter board. Ensure pin 1 is 
oriented correctly, (pin 1 on the cable is usually identified by a red or blue strip.)  

 

Set correct drive type in system CMOS  

 

Refer to applicable manuals for software installation instructions.  

 

 

Important Note: Disconnect power from your computer system before beginning installation. 

 

 

Figure 2.HDD Mounting H

oles 

Summary of Contents for HDD2169

Page 1: ...TOSHIBA AMERICA INFORMATION SYSTEMS STORAGE DEVICE DIVISION IRVINE CALIFORNIA MK3018GAS HDD2169 2 5 INCH HARD DISK DRIVE USER MANUAL Rev 02 11 2006 ...

Page 2: ...CONTENTS Introduction 1 Setup 2 Using the HDD 4 Troubleshooting 5 Specifications 6 Drive Connectors 8 ...

Page 3: ...ring FDB Motor 1 Platter 30 Gigabytes 9 5mm High 12ms Average Seek Time ATA 2 3 4 5 Interface Supports high transfer rates of 100MB sec 2MB Buffer Rotational speed of 4 200rpm MTTF 300 000 Hours Toshiba defines a megabyte MB as 1 000 000 bytes and a gigabyte GB as 1 000 000 000 bytes ...

Page 4: ...e configuration only one of each per port is used for two drive applications Use the information in the following table before setting drive as Master or Slave Master configuration is obtained by setting jumpers A B C D open no jumper present Slave configuration is obtained by setting jumpers C D When B D jumper is installed the drive is configured as cable select If pin 28 Low the drive is Master...

Page 5: ...e Avoid touching the interface connector pins and the surface of PCB Be sure to use ESD proof wrist strap when handling drive The four mounting screws should be tightened equally with 0 3N m 3kgf cm torque The depth should be 3 0mm minimum and 3 5mm maximum Placing Hard Drive inside your Computer Determine mounting configuration the drive can be mounted in either a horizontal or vertical orientati...

Page 6: ...4 USING THE HARD DISK DRIVE MK3018GAS HDD2169 Backing up Data Files To avoid data loss regularly back up the data files on the hard disk drive ...

Page 7: ...d party software is available that breaks the capacity barrier Some suggestions are EZ Drive by Micro House and Disk Manager DiskGo by Ontrack Check with your local computer software supplier for availability or contact the software manufacturer How do I install my 2 5 Toshiba Hard Drive into my desktop or tower system You will need a HDD mounting kit in order to install a Toshiba 2 5 drive into y...

Page 8: ...es and a gigabyte GB as 1 000 000 000 bytes Internal Drive Characteristics Number of Disks 1 Number of Read Write Heads 2 Track Density TPI 56 8K User Data Cylinders 33 280 Logical Cylinders 16 383 Logical Heads 16 Logical Sectors track 63 Bytes per Sector 512 Logical Blocks LBA 58 605 120 Reliability Preventative maintenance None Nonrecoverable read errors 1 error per 1013 bits read Electrical Vo...

Page 9: ...atory The drive satisfies the following standards Underwriters Laboratories UL 1950 Canadian Standard Association CSA C22 2 No 220 No 950 TUV Rheinland EN 60 950 EMC EN50081 1 EN55022 1988 Class B EN60555 2 1987 A1 EN60555 3 77A Co 38 EMC EN50082 1 IEC 801 2 1991 EIC 801 3 1994 IEC 801 4 1988 ...

Page 10: ... GAP050K11617 or equivalent Recommended Host Side Connector Board Straight type Berg 86455 044 86456 044 or equivalent Cable Berg 89361 044 or equivalent Recommended Cable Characteristics Standard diameter 0 32mm 28AWG Characteristics impedance 100 132ohm Max Length 0 46mm max Capacitance 35pF max cable is not included with drive ...

Page 11: ... 2 14 DD 13 15 DD 1 16 DD 14 17 DD 0 18 DD 15 19 GROUND 20 KEY 21 DMARQ 22 GROUND 23 DIOW STOP 24 GROUND 25 DIOR DMARDY HSTROBE 26 GROUND 27 IORDY DMARDY DSTROBE 28 CSEL 29 DMACK 30 GROUND 31 INTRQ 32 IOCS16 33 DA1 34 PDIAG 35 DA0 36 DA 2 37 CS0 38 CS1 39 DASP 40 GROUND 41 5V LOGIC 42 5V MOTOR 43 GROUND 44 RESERVED Note Symbol in front of signal indicates negative logic ...