Interface Signals 

DRIVE INTERFACE SIGNALS

 

PIN SIGNAL PIN 

SIGNAL 

  RESET 

GROUND 

DD 7 

DD 8 

DD 6 

DD 9 

DD 5 

DD 10 

DD 4 

10 

DD 11 

11 

DD 3 

12 

DD 12 

13 

DD 2 

14 

DD 13 

15 

DD 1 

16 

DD 14 

17 

DD 0 

18 

DD 15 

19 GROUND 20  OPEN 

21 DMARQ 22 

GROUND 

23 DIOW/STOP 24 GROUND 

25 

DIOR/ 

-DMARDY 

HSTROBE 

26 GROUND 

27 

IORDY/ 

-DMARDY/-

DSTROBE 

28 CSEL 

29 DMACK 30 

GROUND 

31  

INTRQ 

32 

IOCS16 

33 DA1 34 

PDIAG 

35 DA0 36 

DA 

37 CS0 38 

CS1 

39 DASP 40 

GROUND 

41 

3.3V (LOGIC) 

42 

3.3V (MOTOR) 

43 GROUND 44 

RESERVED 

Note: Symbol () in front of signal indicates negative logic.

 

 

Summary of Contents for HDD1544

Page 1: ...TOSHIBA AMERICA INFORMATION SYSTEMS STORAGE DEVICE DIVISION IRVINE CALIFORNIA MK6006GAH HDD1544 1 8 INCH HARD DISK DRIVE USER MANUAL ...

Page 2: ...CONTENTS Introduction 1 Setup 2 Using the HDD 3 Specifications 4 Drive Connectors 6 ...

Page 3: ...ON MK6006GAH HDD1544 HARD DISK DRIVE General Features 1 8 sized drive 2 Platter 60 Gigabytes 8mm High 15ms Average Seek Time ATA 6 Interface Ultra DMA 100 2MB Buffer Rotational speed of 4 200rpm MTTF 300 000 Hours ...

Page 4: ...tronstatic discharge can also damage the drive You should ground yourself prior to handling the drive Figure 1 MK6006GAH Side View Installation Notes Do not apply any force to the top cover except the screw areas on top cover Maximum force to the specified area is 2N important Note Disconnect power from your computer system before beginning installation ...

Page 5: ...3 USING THE HARD DISK DRIVE MK6006GAH HDD1544 HARD DISK DRIVE Backing up Data Files To avoid data loss regularly back up the data files on the hard disk drive ...

Page 6: ...Non recoverable read errors 1 error per 1013 bits read Electrical Voltage 3 3V 5 Power Consumption Start 1 2W typ Seek 1 4W typ Read Write 1 4W typ Sleep 0 08W typ Energy Consumption Efficiency 0 005W GB avg Shock Operating 4 900m s2 500G 2msec Non Operating 14 700m s2 1500G 1msec Formatted Capacity 60 0GB Rotational Speed 4 200rpm Avg Rotational Latency 7 14 ms Spin up Time 3 5sec typical Buffer ...

Page 7: ...Width 2 13 54 0mm Depth 3 09 78 5mm Weight 2 19oz 62g typ Regulatory The drive satisfies the following standards Underwriters Laboratories UL 1950 Canadian Standard Association CSA C22 2 No 950 TUV Rheinland EN 60 950 BSMI 3902C799 ...

Page 8: ...RS MK6006GAH HDD1544 HARD DISK DRIVE Figure 1 MK6006GAH HDD INTERFACE CONNECTOR Interface Connector Drive Side Connector MCD D50 Series by DDK Connectors Recommended Host Side Connector MCD D50 Series by DDK Connectors ...

Page 9: ...DD 13 15 DD 1 16 DD 14 17 DD 0 18 DD 15 19 GROUND 20 OPEN 21 DMARQ 22 GROUND 23 DIOW STOP 24 GROUND 25 DIOR DMARDY HSTROBE 26 GROUND 27 IORDY DMARDY DSTROBE 28 CSEL 29 DMACK 30 GROUND 31 INTRQ 32 IOCS16 33 DA1 34 PDIAG 35 DA0 36 DA 2 37 CS0 38 CS1 39 DASP 40 GROUND 41 3 3V LOGIC 42 3 3V MOTOR 43 GROUND 44 RESERVED Note Symbol in front of signal indicates negative logic ...

Reviews: