192
GX9 ASD Installation and Operation Manual
Upper Limit Frequency Adjustment
Program
Terminal
Analog Input Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Upper Limit
. When enabled, either
VI/II
or
RR
may be used
as an input source for the modification of the
Upper Limit
setting.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F651
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Acceleration Time Adjustment
Program
Terminal
Analog Input Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Acceleration Time
. Selecting either
VI/II
or
RR
enables this
feature. The selected input is used as a multiplier of the programmed
Acceleration Time
setting. The multiplication factor may be from 1 to 10.
Note:
An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F652
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Deceleration Time Adjustment
Program
Terminal
Analog Input Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Deceleration Time
. Selecting either
VI/II
or
RR
enables this
feature. The selected input is used as a modifier of the programmed
Deceleration Time
setting.
Note:
A deceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F653
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Torque Boost Adjustment
Program
Terminal
Analog Input Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Torque Boost
setting. Selecting either
VI/II
or
RR
enables
this feature. The selected input is used as a modifier of the programmed
Torque
Boost
setting.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F654
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Summary of Contents for GX9
Page 2: ......
Page 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv GX9 ASD Installation and Operation Manual ...
Page 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Page 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Page 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Page 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Page 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Page 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Page 268: ......