background image

Meets or Exceeds 

Your Specifications

GX7 Specifications

Standard Specifications

Item 

Voltage Class 

600 VAC

Maximum HP 

500 HP

600 HP

700 HP 

800 HP 

Drive Rating (A) 

481 A

601 A 

698 A

770 A

Dimensions 

95”H x 32”W x 30.5”D 

Power Requirements 

Output Frequency 

0 to 299 Hz 

Control Power 

DC Bus Control Power 

Tolerance 

Voltage: ±10%; Frequency: ±2% 

Control Specifications 

Control Method 

Sine Wave PWM System; Flux Field Current Vector Control 

V/Hz Control 

Constant Torque, Variable Torque, Open-Loop Vector, Auto or Manual Torque Boost, 5-Point V/Hz Custom Curves 

Overload Rating 

130% for 120 Seconds; 110% Continuous 

Frequency Setting 

Rotary Encoder Integrated into EOI, 0 to 10 V, ±10 V, 4 to 20 mA, Binary Input, Motorized Potentiometer Input 

Frequency Precision 

Analog Input: ±0.2% of Maximum Output Frequency; Digital Input: ±0.01% of Maximum Output Frequency

Frequency Resolution 

Panel Operation: 0.01 Hz;  Analog Input 10 to 12-Bit A to D Converter: 0.1 Hz

Acceleration / Deceleration 

0.1 to 6000 Seconds 

Speed Regulation 

Up to 0.1%; 60:1 Speed Range 

Torque Setting

±250% of the Rated Torque

Set Point Control (PID) 

Proportional Gain, Integral Gain, Feedback Settings Upper/Lower Deviation Limits, Feedback Source Delay Filter, Feedback Settings 

Differential Gain 

Analog Inputs 

Four Programmable: (1) 4 to 20 mA, (1) 0 to 10 V, (1) -10 to +10 V, (1) 1 to 10kΩ Potentiometer Connection 

Analog Outputs 

Two Programmable to 31 Functions 

Discrete Inputs 

Eight Programmable to 67 Functions; Expandable to N-Value

Output Contacts 

Three Output Terminals, Programmable to 52 Functions; Form C Contacts Rated 250 V AC, Two Amps Inductive 

Signal Isolation 

Available Three-Channel Signal Isolation for AM/FM Outputs and II Terminal Input, Rated at 750 V 

Power Terminals

Input (L1, L2, L3) Output (T1, T2, T3) DCL (PO, PA), DBR (PA, PB), DCBUS (PA, PC)

Control Board 

Communication Ports 

RS232/485 and TTL Ports Standard 

Data Transmission 

Profibus, DeviceNet, Modbus RTU, , Metasys, Ethernet (Some Devices are External) 

Main Protective 

Functions

Current Limit, Overcurrent, Overvoltage, Undervoltage, Load-Side Short Circuit, Load-Side Ground Fault,  Armature Short; Overtorque, 

ASD Overload, Motor Overload, Heatsink Overheat, Open Output Phase, Loss of Feedback, CPU Error, Communications Error

Soft Stall 

Automatic Load Reduction Control During Overload 

Retry 

Can Automatically Clear Fault Upon Trip; Programmable to 10 Tries with up to 10 Seconds Between Tries 

Restart 

Restart into a Rotating Motor 

Interface 

LCD/EOI (Liquid Crystal 

Display/Electronic 

Operator Interface) 

Backlit LCD Display; Ability to Display Multiple Parameters on One Screen; Keypad may be Operated from External Power Source; 

Software is Flash Upgradeable; Includes Multi-Function Rotary Encoder

LED Indicators

Run (Red)/Stop (Green), Remote/Local (Green), DC Bus Charge Indication (Red) 

Keys 

Local/Remote, Monitor/Program, Run, Enter, ESC, Stop/Reset, Up, Down 

Monitoring 

Main Display Shows Two Monitored Items Continuously, or Scrolls Up to 40 Items

Selectable Display Units 

User-Selectable and Configurable along with Scaling Factor Multiplier; Voltage Display Selectable: Volts or %; 

Current Display Selectable: Amps or %. 

EOI Communication Ports 

RS232/485 and TTL Ports Standard 

Remote-Mount Display 

Remote Mountable Up to 1000 Feet

Construction 

Enclosure 

NEMA 1, IP20, Gasketed and Filtered 

Panel Construction 

Free-Standing, Front-Maintenance Type, Top or Bottom Access for Motor and Power Cables 

Cooling 

Forced-Air Cooled Top-Mounted Fans may be Removed During Shipment or Installation

Color 

ANSI-61 Gray 

Ambient Conditions 

Ambient Temperature 

-10 to 40°C (-14 to 104°F) 

Humidity 

Max. 95% (Non-Condensing) 

Altitude 

1000 Meters (3300 Feet) Above Sea Level or Less 

Installation 

Indoor, No Direct Sunlight, Protect from Corrosive Gases and/or Explosive Gases 

Standards

Electrical Compliance

NEC, ANSI 

Summary of Contents for GX7 Series

Page 1: ...GX7 Series ADJUSTABLE SPEED DRIVES ...

Page 2: ...s designed to handle the most extreme conditions continuing the G Series tradition of delivering a robust performance platform Small Footprint Top or Bottom Cable Entry Exit Molded Case Circuit Breaker with Through the Door Operator Removable Capacitor Assembly for Easy Serviceability Removable Terminal Strip 12 Gauge Steel Enclosure User Friendly Electronic Operator Interface EOI Heatsink Out the...

Page 3: ...10 continuous current 130 up to 120 seconds the GX7 can withstand load conditions that would cause other drives to fail The GX7 is ready for continuous trouble free operation in the most demanding manufacturing environments In addition it is designed for an operating environment of 10 to 40 C at elevations of 1000 to 1000 meters Industrial Solutions 32 95 Variety of Communication Options In the fa...

Page 4: ...id in Diagnostics Flash Upgradeable EOI Software Help from Toshiba Customizing Application Specific Wizards Standard Keypad Design for Low Voltage and Medium Voltage Drives Monitor Software The free monitor software allows the user to monitor and control critical operational parameters using serial communication The software contains real time graphing a very useful tool for data analysis which al...

Page 5: ...ontrol Board Communication Ports RS232 485 and TTL Ports Standard Data Transmission Profibus DeviceNet Modbus RTU Modbus Metasys Ethernet Some Devices are External Main Protective Functions Current Limit Overcurrent Overvoltage Undervoltage Load Side Short Circuit Load Side Ground Fault Armature Short Overtorque ASD Overload Motor Overload Heatsink Overheat Open Output Phase Loss of Feedback CPU E...

Page 6: ...Be sure to visit our website located at www toshiba com ind for the latest information on Toshiba products and services Customer Support Services Toshiba offers 24 hour service nationwide For assistance of any type call 1 800 231 1412 Medium Voltage Motor G7 Drive ADJUSTABLE SPEED DRIVES MOTORS CONTROLS UPS INSTRUMENTATION PLC INDUSTRIAL DIVISION 13131 West Little York Road Houston Texas 77041 Tel...

Reviews: