6F2S1916 (0.
5
)
GIF200
- 13 -
Technical data
Ratings
Power supply:
24Vdc - 250Vdc
(Operative range: 19.2 - 300Vdc)
Burden:
Less than 8W
ITU-T G.703 Interface
Communication interface:
ITU-T G.703 (64kbps, co-directional)
ITU-T G.703 (64kbps, contra-directional or centralized clock)
DB25 connector
C.37.94 Interface
Operative Range:
Wavelength:
Connector type:
Fibre type:
Output level:
Receiver sensitivity:
Less than 2km
820nm
ST
62.5/125
m GI fibre
Mean optical power: > −19 dBm and < −11.0 dBm (62.5
m)
Mean optical power: between −32 dBm and < −11 dBm
Atmospheric Environment
Temperature
Humidity
Enclosure Protection
IEC60068-2-1/2
IEC60068-2-78
IEC60529
Operating range: -10
C to +55
C.
Storage / Transit: -25
C to +70
C.
56 days at 40
C and 93% relative humidity.
IP20
Functions
Functions and display
Clock
Free-running oscillation is available
LED
Power, Tx, Rx, CLK, error indicators are provided