![Toshiba GD-1221 Service Manual Download Page 40](http://html.mh-extra.com/html/toshiba/gd-1221/gd-1221_service-manual_424258040.webp)
GD-1220/1221
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
DIALING/COMMUNICATION CONTROL
3 - 6
- Cancellation during the transmission
If the [CLEAR/STOP] button is pressed during the direct transmission or memory input, the dis-
play to confirm the cancellation appears. The communication is finished normally regardless of
the presence/absence of the next page or mode changes by pressing the [CLEAR/STOP] button.
If the [CLEAR/STOP] button is pressed anytime except during the transmission of the image
data, DCN is forcibly sent to terminate the communication.
To cancel the job during the memory transmission or the polling transmission job, press the [JOB
STATUS] button on the External Keyboard, select the transmission job to cancel, and then press
the [ ] button on the LCD display.
Transmtter
CED
NSF•CSI•DIS
NSS•TSI•DCS
Receiver
Image signal
Training
TCF
CFR
MCF
EOP
DCN
[JOB STATUS] button