— 5 —
Alignment Point Location on Base Main PCB and Base RF PCB
Receiver Section
Connections
Preset
Place the Base Unit in RX SENS mode (step 11) in accordance with the precedure on page 4.
AC Voltmeter
BASE Unit
AF
Test Point
Dummy Load
(600-ohm)
RF SG
AC 120V
60Hz
J2
DC IN 9V Jack
+
RF
Test Point
J1
TEL Line
Jack
AC
Adapter
DC Voltmeter
-
+
-
Base Main PCB
RT1
RT2
L4
J1
TEL LINE Jack
J2
DC IN 9V Jack
RF Test Point
AF Test Point
Alignment Procedure
step
1
2
3
Preset to
SG: 1mV
No modulation
SG: 1mV
1 kHz – 8kHz
deviation
SG:
−
6.0dB
µ
V
No modulation
Remarks
Connect the RF Signal Generator to the RF test point on the Base MAIN
PCB. Make sure that the frequency is 902.952467 MHz.
Connect the DC Voltmeter to the AF test point. Adjust L4 to indicate DC
1.00 V.
Connect the AC Voltmeter across a 600-ohm dummy to the Telephone Line
Jack. Adjust RT2 for a -12dBm reading on the AC voltmeter.
Adjustment
L4
(Discriminator
Voltage)
RT2
(RX AF
Voltage)
RT1
(SQ Point)
Press thePress the
SKIP / FF key to enter the TEST Mode 12.
Make sure that the frequency of RF SG output is 902.952467 MHz.
Adjust RT1 to turn to the point where the LED indication is just vibrated.
Summary of Contents for FT-8981
Page 1: ...SERVICE MANUAL PUBLISHED IN JAPAN May 2001 FILE NO 2B0 200104 FT 8981 CORDLESS TELEPHONE ...
Page 9: ... 8 BLOCK DIAGRAMS Base Unit ...
Page 10: ... 9 Handset ...
Page 12: ...Handset 12 13 FT8981 Sche p65 01 05 25 13 21 Page 9 Adobe PageMaker 6 5J Win ...
Page 27: ... 28 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 28: ... 29 Handset Main PCB ...
Page 29: ... 30 WIRING DIAGRAMS Base Unit ...
Page 30: ... 31 Handset ...