19
7. The voice of the caller cannot be heard (incoming call).
Can the base and handset be
connected?
See 3. The base and handset
cannot be connected.
OK
NG
The 1 kHz, 77.5mV sine
waveform is applied to TEL-
line of the base, can the 1 kHz
sine waveform from the Q3
collector be fed?
Check the base TEL-line
circuit and REPLAY control
circuit.
NG
Check whether there is the
1 kHz sine wavefor m at
pin 24 of IC1.
Check Q4 and its peripheral
circuit.
NG
OK
OK
Check whether there is the
1 kHz sine wavefor m at
pin 20 of IC1.
Check IC1 and its peripheral
circuit.
NG
OK
TX output signal from the
base is detected by the liner
detector, can the 1 kHz sine
waveform be fed?
Check base RF unit.
NG
OK
Check whether there is the
1 kHz sine waveform at pin 9
of IC401 on the handset unit.
Check IC401, Q401 and
their peripheral circuit.
NG
OK
Check whether there is the
1 kHz sine waveform at pin 3
of IC403.
Check RT402, Q402 and
their peripheral circuits.
NG
OK
Check whether there is the
1 kHz sine waveform at the
pin 18 of IC403.
Check IC403 and its
peripheral circuit.
NG
OK
Check whether there is the
1 kHz sine waveform at pin
1, 2 of SP801.
Check Q405, Q406 and its
peripheral circuit.
NG
OK
Check SP801 and W801,
W802.
Check handset RF unit.
NG
OK
Check whether there is the
1 kHz sine wavefor m at
“MOD” RF unit.
Check RT3 and its
peripheral circuit.
NG
OK
Summary of Contents for FT-8009
Page 1: ...48 CORDLESS TELEPHONE PUBLISHED IN JAPAN Aug 1999 SERVICE MANUAL FILE NO 2B0 9901 FT 8009 ...
Page 8: ...7 BLOCK DIAGRAMS Base Unit ...
Page 9: ...8 Handset ...
Page 10: ...9 10 SCHEMATIC DIAGRAMS Base Unit ...
Page 11: ...11 12 Handset ...
Page 25: ...26 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 26: ...27 Handset Main PCB ...
Page 27: ...28 WIRING DIAGRAMS Base Unit ...
Page 28: ...29 Handset ...
Page 31: ...32 Handset 7 8 4 1 16 17 17 5 10 15 11 12 2 9 6 13 14 3 17 MAIN PCB ASSY RF MODULE HANDSET ...
Page 45: ......